8-21
BASIC MANUAL
8
SET MODE
WLAN Set
» SET >
WLAN Set
Subnet Mask (Valid after Restart)
(Default: 255.255.255.0(24 bit))
Sets the subnet mask to connect to your PC or
Local Area Network (LAN), through your Router.
Default Gateway (Valid after Restart)
(Default: . . . .)
Sets the Default Gateway of the IC-705.
When you remotely control the IC-705 or
use the Internal Gateway function, a Default
Gateway setting is required.
Primary DNS Server (Valid after Restart)
(Default: . . . .)
Sets the Primary DNS Server address.
2nd DNS Server (Valid after Restart)
(Default: . . . .)
If there are two DNS server addresses, sets the
secondary DNS server address.
» SET >
WLAN Set
Network Name
If you are operating the IC-705 using the
optional RS-BA1 or transferring a picture to the
IC-705 using the optional ST-4001W, enter a
network name of up to 15 characters.
» SET > WLAN Set >
Remote Settings
Network Control (Valid after Restart)
(Default: OFF)
Selects whether or not to remotely control the
IC-705.
•OFF: Disables remote control of the IC-705.
•ON: Enables remote control of the IC-705.
Control Port (UDP) (Valid after Restart)
(Default: 50001)
Sets a port number for the control signal
transfers between the IC-705 and the remote
station, when you remotely control the IC-705.
Serial Port (UDP) (Valid after Restart)
(Default: 50002)
Sets a port number for the serial data transfers
between the IC-705 and the remote station,
when you remotely control the IC-705.
Audio Port (UDP) (Valid after Restart)
(Default: 50003)
Sets a port number for the audio signal transfers
between the IC-705 and the remote station,
when you remotely control the IC-705.
Internet Access Line (Valid after Restart)
(Default: FTTH)
Selects the Internet access line setting for the
IP remote control.
» SET > WLAN Set > Remote Settings
>
Network User1
» SET > WLAN Set > Remote Settings
>
Network User2
Network User1 ID
Network User2 ID
Sets a user name of up to 16 characters to use
when you remotely control the IC-705.
Network User1 Password
Network User2 Password
Sets a user password.
L
The password must include a minimum of 8
characters and a maximum of 16 characters.
L
You cannot use a password that consists of
exactly the same characters.
Network User1 Administrator
(Default: NO)
Network User2 Administrator
(Default: NO)
Selects whether or not to set the user as an
administrator.
Only an authorized user can disconnect
communication between the IC-705 and the
remote station.
» SET > WLAN Set >
Remote Settings
Network Radio Name
(Default: IC-705)
Sets the IC-705’s name of up to 16 characters
that is displayed in the remote control software,
when you remotely control the IC-705.