308DUO V1.1.0
Synchronous Balance Charger/Discharger
- 26 -
308DUO Parameters Setup
308DUO Parameters Setup
Press
TAB/SYS
button for
2 seconds
on the initial interface to enter the
SYSTEM MENU
interface, setting and testing of
the system parameters, storage and servo can be completed on this interface.
Charger Setup
After setting all parameters, click “
” to save and return to the previous interface.
Temp. & Fans Setup
Select
SYSTEM MENU
→
Charger Setup
→
Temperature&Fans
to enter the setup interface, after setting click “
”to
save and return to the previous interface.
Note:
When the charger’s internal temperature reaches the
ON Temperature
, the fan will start
automatically to dissipate heat, and adjust speed automatically depends on the temperature
increasing or decreasing. When the temperature exceeds the
Power Reduce
temperature, the
charger will stop increasing (temp. shown in orange) by reducing the highest power limit. When the
temperature reaches
Shut Down
temperature, the charger will shut down. [When temp. >
Shut
Down-3
, the temperature is shown flashing in red]
.
When the temperature is lower to the
ON
Temperature
, the fan will keep running within the setting time of
OFF Delay Time.
1: Charger Setup Menu
2: Temp. & Fans Setup 3: Beep Tone Setup
4: LCD Setup 5: Output Power Setup
6: Power Supply Setup
7: Save & Load Configuration Setup
8: Calibration Setup 9:Language Setup
10:Calibration
11: Extra- Function
12: Log Files Manage 13: Servo Test
14: Pulse Test
1
2
3
4
5
6
7
8
9
11
12
13
14
10
1: Temperature:
Unit:
Celsius(default),Fahrenheit
Shut Down:
60
℃
-75
℃
;default:75
℃
Power Reduce:
5
℃
-20
℃
;default:10
℃
2:Cooling Fans:
ON Temperature:
30
℃
-50
℃
;default:40
℃
OFF Delay Time:
0Min-10Min;default:2Min