308DUO V1.1.0
Synchronous Balance Charger/Discharger
- 16 -
Note: 1. Channel Mode has asynchronous, synchronous available, see more details on
Page10
2. If select synchronous mode, the maximum charge/discharge current setting will change from
30A to 50A.
3. If tick
Auto saves before the program runs
, the parameters set on the
Run program
will be
saved automatically, and the
Run Program
will display “
Auto save
” ( shown in the following
left picture), otherwise it will display “
Don’t save!
” (shown in the following right picture); for
the built-in program, the
Auto save before the program runs
option is ticked by default.
4. If tick
Log save to SD card
, the log files will be saved to SD card when running program, and
vice versa.
LiPo/LiIo/LiFe Battery Charge/Discharge Setup
After adding a program, it will switch to LiPo/LiIo/LiFe battery in
Type
option on the
MEMORY SETUP
interface, and
set the number of
cells
and
capacity
, if there is no setting for the number of cells, the charger will set
Auto
by default.
After editing all parameters for the program, click "
" to save and return to the previous interface.
As shown in the above picture, the program of LiPo, LiIo, LiFe battery has:
Charge, Storage, Discharge, Cycle and
Balance Only.
LiPo/LiIo/LiFe Battery Charge Setup
Select
Program
→
Charge
to enter
Charge
setup interface.
Chg Current:
0.05A-30A; default: 2A
Chg Mode:
Slow Balance, Normal Balance( default),
Fast Balance, User Balance, Not Balance
Chg End Current:
1%-50%; default: 10%
Chg Cell Volt:
3.85V/Cell-4.35V/Cell;
Default: 4.2V/Cell
Cells:
Auto(default), 1-8S