308DUO V1.1.0
Synchronous Balance Charger/Discharger
- 25 -
NiZn Battery Charge Advanced Setup
Click "
" to enter
NIZN ADVANCED SETUP
interface, see details about setting on Page19 LiPo/LiIo/LiFe
Battery Charge Advanced Setup.
NiZn Battery Charge Safety Setup
Click "
" to enter
CHARGE SAFETY SETUP
interface, see details about setting on Page19 LiPo/LiIo/LiFe Battery
NiZn Battery Discharge Setup
Select
Program
→
Discharge
to enter
Discharge
setup interface
Note: 1.The charger first discharges with constant current (CC) according to the user setting then turns
to constant voltage (CV) when it reaches the discharge voltage. In the CV phase the current
gradually falls, and the charger will terminate discharging when the current falls below the
percentage of the configured discharge current.
2. Regenerative mode has three available settings
: OFF, To input, To channel
, see more details on
Page38
To Channel Setup
Switch to
To channel
mode on
Regenerative Mode
interface,
click
“
”
to enter
To channel
setup interface, see
details about setting on Page20 To Channel Setup.
NiZn Battery Discharge Advanced Setup
Click
“
”
to enter
NiZn DISCHARGE ADVANCED SETUP
interface, see details about setting on Page20
LiPo/LiIo/LiFe Battery Discharge Advanced Setup.
NiZn Battery Discharge Safety Setup
Click
“
”
to enter
DISCHARGE SAFETY SETUP
interface, see details about setting on Page19 LiPo/LiIo/LiFe
NiZn Battery Cycle Setup
Select
Program→ Cycle
to enter
Cycle
setup interface,
see details about setting on Page21 LiPo/LiIo/LiFe Battery Cycle
Discharge Current:
0.05A-30A
;
default: 2A
Discharge Voltage:
0.9V/Cell-1.6V/Cell
;
default: 1.1V/Cell
End Current:
1%-100%; default: 50%
Regenerative Mode:
OFF(default),To input, To channel