308DUO V1.1.0
Synchronous Balance Charger/Discharger
- 23 -
NiMH/NiCd Battery Cycle Setup
Select
Program
→
Cycle
to enter
Cycle
setup interface, see details about setting on Page21 LiPo/LiIo/LiFe Battery Cycle
Pb Battery Charge/Discharge Setup
After adding program, it will switch to Pb battery in
Type
option on the
MEMORY SETUP
interface. Set the number of
cells
and
capacity
, after editing all parameters for program, click"
"to save and return to the previous interface.
As shown in above picture, the program of Pb battery has the following modes:
Charge, Discharge
and
Cycle.
Pb Battery Charge Setup
Select
Program→Charge
to enter
Charge
setup interface.
Note: 1. The charger first charges with constant current (CC) according to the user setting then turns to
constant voltage (CV) when the charging voltage reaches the peak point. In the CV phase the
current gradually falls, and the charger will terminate charging when the current falls below
the percentage of the configured charge current.
2. Charge mode has
Normal, Reflex
two modes available, about the
Reflex
mode (Reflex) please
Pb Battery Charge Advanced Setup
Click "
" to enter
PB ADVANCED SETUP
interface,
Note: When charging the over-discharged battery, the charger will detect if the cell voltage is larger
than the restore voltage, if larger, it will pre-charge the battery with restore current, if within the
setting restore time, the cell voltage rises to the normal value then it will turn to the charging
program; otherwise it will stop running.
Chg Current:
0.05A-30A; default: 2A
Chg Mode:
Normal (default), Reflex
Chg End Current:
1%-50%; default: 10%
Chg Cell Volt:
2V/Cell-2.6V/Cell; Default: 2.4V/Cell
Cells:
1-15S; default: 6S
Restore Lowest Voltage:
0.5V/Cell-2.5V/Cell; default: 1V/Cell
Restore Charge Time:
1Min-5Min;default: 3Min
Restore Charge Current:
0.02A-0.5A;default: 0.1A