Disassembly ID-0300
Ice Base Plate
Agitator
Wingnut (3)
Silicone
Drain Guide
Mounting Plate
Screws (3)
H20 Dispense Sol
Drain Guide Hose
Removal and Replacement of Ice Hopper, Extruder, Auger, & Evaporator
▪
Ice Hopper
1. Turn off the power switch and the circuit breaker, unplug the power cord from the outlet, close the valve on the
water supply line, and remove all panels except for the back.
2. Remove drain guide & drain guide hose, then follow the previous instructions to remove water reservoir.
3. Remove the dump solenoid by removing the hose & clamp, but keep it attached to the mounting bracket and
remove the bracket and dump solenoid as one piece.
4. Remove the water dispensing solenoid by disconnecting the wire terminals from the coil & removing it & the
mounting plate as one piece.
5. Disconnect the ice dispensing solenoid & LED/UV light from the PCB.
6. Remove the ice hopper cover.
7. Remove the agitator assembly and ice base plate, individually.
8. Remove the 3 wingnuts located underneath the ice hopper.
9. Lift up on the ice hopper to remove it from the evaporator assembly.
31
Содержание ID-0300-AN
Страница 1: ...ID 0300 AN INSTALL SERVICE MANUAL...
Страница 2: ...ID 0300 Specs 2...
Страница 3: ...ID 0300 Specs Water drain connections are underneath the dispenser 3...
Страница 16: ...Wiring Diagram 16...
Страница 41: ...Parts Breakdown ID 0300 41...
Страница 42: ...Parts Breakdown ID 0300 42...
Страница 43: ...Parts Breakdown ID 0300 43...
Страница 44: ...Parts Breakdown ID 0300 44...
Страница 45: ...Thank You 1 15 2022...