Disassembly ID-0300
Removal and Replacement of Expansion Valve
! Caution !
Sometimes moisture in the refrigeration system exceeds the drier’s capacity, causing the expansion valve to freeze.
Whenever the refrigeration system is open, replace the drier and do not open the new drier until all repairs and part
replacements are complete.
1. Turn off the power switch and the circuit breaker, unplug the power cord from the
outlet, and then remove the front lower panel & the left side panel.
2. Recover the refrigerant and store it in an approved container.
3. Remove the sensing bulb from the suction line.
4. Remove the expansion valve cover and braze out the expansion valve.
5. Braze in new expansion valve while flowing 3-4 PSIG nitrogen gas.
!
W
arning !
Wrap a wet cloth around the valve body to prevent it from
heating up. (The body should not exceed 249°F when
soldering.)
6. Replace with a new dryer.
7. Check that there are no leaks with nitrogen gas at 140 PSIG and soap bubbles.
8. Weigh in refrigerant charge. Refrigerant type and quantity are determined by product nameplate.
9. Replace the sensing bulb onto the suction line, tighten it with a band, and wrap it completely with insulation material
(Foam PE).
10. Wrap the expansion valve (TXV) with expansion valve cover (insulation material) to prevent any air gaps.
11. Assemble the panels, connect the power, turn on the circuit breaker, and turn on the power switch.
Expansion Valve
ID-0300
28
Содержание ID-0300-AN
Страница 1: ...ID 0300 AN INSTALL SERVICE MANUAL...
Страница 2: ...ID 0300 Specs 2...
Страница 3: ...ID 0300 Specs Water drain connections are underneath the dispenser 3...
Страница 16: ...Wiring Diagram 16...
Страница 41: ...Parts Breakdown ID 0300 41...
Страница 42: ...Parts Breakdown ID 0300 42...
Страница 43: ...Parts Breakdown ID 0300 43...
Страница 44: ...Parts Breakdown ID 0300 44...
Страница 45: ...Thank You 1 15 2022...