54
5.7. Precautionary measures to be taken by the operator
IBS-Parts Cleaning Devices conform to type class A 1 (EN 12921-3; 3.15.1).
DANGER!
A danger area which is appropriate for the operating conditions (e.g. geometry and surface area of workpieces, intensity
of cleaning) must be defined. For normal cleaning processes, IBS recommends a danger area of 2 m around the device.
The danger area identified by means of a risk assessment:
∙ Must be designated a fire hazard area
∙ Must remain free of obstructions in order to allow unimpeded access at all times
∙ Must be equipped with effective natural ventilation
∙ Smoking is not permitted in the danger area
∙ Naked flames or other sources of ignition are not permitted in the danger area
∙ Keep everything as clean as possible when working with cleaning agents, oils and lubricants
∙ Operating and maintenance personnel must receive proper training
∙ The operating instructions and the standard operating procedure must be attached to the device
6. OPERATING THE MACHINE
6.1. Controls
The device is switched on with a foot-operated safety switch.
6.2. Assembly and adjustment
6.2.1. Assembling the Parts Cleaning Device M and MD (M-500 see attachement)
∙ Remove the packaging.
∙ Insert the two base frames (1) into the round pipe sleeves (2) (located directly underneath the tray).
∙ Attach the two cross braces (3) to the base frames using the bolts supplied (4).
∙ Place the 200-litre drum (5) in the collecting tray (optional) (6) with the screw fitting facing upwards and remove the 2” bung adapter
in the drum casing.
∙ Place the assembled device over the drum (5).
1
6
5
7
13
11
4
2
10
3
9
EN
IBS-BA_Typ_M_MD_M500-DE_CZ_PL_ES_EN_11.2022
Содержание M-500
Страница 14: ...12 DE IBS BA_Typ_M_MD_M500 DE_CZ_PL_ES_EN_11 2022...
Страница 26: ...24 CZ IBS BA_Typ_M_MD_M500 DE_CZ_PL_ES_EN_11 2022...
Страница 38: ...36 PL IBS BA_Typ_M_MD_M500 DE_CZ_PL_ES_EN_11 2022...
Страница 50: ...48 ES IBS BA_Typ_M_MD_M500 DE_CZ_PL_ES_EN_11 2022...
Страница 62: ......
Страница 63: ...Anhang Attachment...