4
Instruction Manual C100
3 coloured LED column
Numeric display
Mode / Units
Programming Menu
Keypad
B/C100-ind4
B/C100-ind2
B/C100-ana4
Column display ranges
± 1,5000 mm ± 0,15000"
The column display features 3 colours ( red, green, yellow )
±
0,5000 mm
± 0,05000"
with automatic colour selection corresponding to the given
± 0,1500 mm
± 0,01500"
tolerance limits.
± 0,0500 mm
± 0,00500"
It is possible to programme up to 4 tolerance limits.
± 0,0150 mm
± 0,00150"
Tolerance limits are marked on the column display.
± 0,0050 mm
± 0,00050"
Notice:
The measurement range of the column display can be set in the Setup menu to a fixed value or to
Auto
mode.
In AUTO mode the column gauge automatically selects the smallest possible range on the base of the
programmed tolerances. The selected range is displayed in the upper right corner of the front panel.
1.3
Front panel and rear
Measuring modules
Column display range
and unit
Probe connectors
Analogue in-/ outputs
Type label
RS232 male connector
Tol. Out socket
Power switch
Mains inlet
Tolerance marks
(max.4)
Type label
For future expansion
Connectors sketch