16
Instruction Manual C100
In this menu the inductive probe inputs or voltage inputs A....D are assigned to the gauge ( or gauges ).
Any combination of the inputs ( i.e. A + B, A - B, A+B - C+D, ... ) is possible.
Besides, you can assign a fixture coefficient ( multiplier ranging 0,01 to 9,99 ) to each input.
Example : a) A + B
→
1.00 A
c) A - C
→
0.50 A
1.00 B
2
0.00 B
0.00 C
- 0.50 C
0.00
D
0.00
D
b) A - B
→
1.00
A
d)
A+2B-C
→
1.00 A
- 1.00 B
2
2.00 B
0.00 C
- 0.50 C
0.00 D
0.00 D
Notice :
When all probe inputs are disabled (
0.00
A...D ) measurements are no longer possible and
the error message
'Err. 1'
appears on the numeric display.
If the same probe input or analogue input is selected on more than one gauge
( Gauge 1…4 ) and the operation mode is “Auto recognition” the “Err. 8” will appear on the
numeric display.
The probe input or analogue input change the measurement result on more than 1 gauge
( Gauge 1…4 ) and auto recognition mode does not work.