Note:
The order of installation is important. You must install the IBM Netfinity
Hot Plug for Windows NT Server 4.0 package before you install the IBM
Netfinity 10/100 Fault Tolerant Adapter driver. If you install the adapter
device driver before the PCI Hot Plug Solution package, the adapter device
driver will not recognize the hot-plug code. This happens because the
adapter device driver only checks the NT registry for the Hot Plug package
during installation. If the PCI Hot Plug Solution package is added after the
adapter device driver is installed, the adapter must be removed and added
again in order for it to detect the PCI Hot-Plug Solution code.
To install the IBM Failover DMI Agent:
1.
Download the DMI EXE file from the xSeries Support web page and extract the
files onto a diskette.
2.
Insert the diskette into the diskette drive.
3.
From the Start menu, select the
Run
option.
4.
Type A:\SETUP.EXE in the Open box.
5.
Click
Ok
. The setup wizard opens.
6.
Follow the instructions that are given by the setup wizard until the program is
installed.
7.
Restart the server.
To install the IBM PCI Hot Plug Solution package:
1.
Download the IBM PCI Hot Plug Services EXE file from the xSeries Support
web page and extract the files onto a diskette.
2.
Log on to Windows NT Server as a user in the Administrator group.
3.
Insert the diskette into the diskette drive.
4.
From the Start menu, select the
Run
option.
5.
Type A:\SETUP.EXE in the Open box.
6.
Click
OK
. The Setup wizard opens.
7.
Follow the instructions given by the setup wizard until the program is
installed.
Windows NT Server failover setup:
To install the IBM Netfinity 10/100 Fault Tolerant Adapter device drivers:
1.
Add the redundant NIC adapter according to the instructions that are provided
with the adapter.
2.
Use the ServerGuide CDs to install the AMD PCNet Ethernet Family adapter
device driver.
3.
Do not select the Grouping box at this point; you must first restart the machine.
4.
From the Windows NT Server desktop, select
Control Panel
, then select the
Network
icon, then select the
Adapters
tab.
5.
Highlight one of the adapters that will be in the redundant pair and then click
the
Properties...
button.
6.
Check the Grouping box. This will show the possible combinations for
redundant pairs.
7.
Select the adapter pair you want and then select
OK
. Note that the integrated
Ethernet controller is located at PCI bus A, slot 2.
Two options are available for recovering from a failover condition. The options
are determined by the Enable for DMI / Hot Swap Support checkbox. If the
IBM Netfinity Hot Plug PCI for Windows NT Server 4.0 package is installed,
Installing options
71
Содержание xSeries 342 2RX
Страница 1: ...Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Страница 2: ......
Страница 3: ...Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Страница 42: ...Using the SCSISelect utility program 34 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Страница 110: ...102 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Страница 114: ...106 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Страница 127: ...Related service information 119...
Страница 128: ...120 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Страница 129: ...Related service information 121...
Страница 130: ...122 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Страница 131: ...Related service information 123...
Страница 132: ...124 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Страница 133: ...Related service information 125...
Страница 134: ...126 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Страница 147: ...Related service information 139...
Страница 148: ...140 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Страница 149: ...Related service information 141...
Страница 157: ......