background image

A highly available and expandable, rack-dense, 2U dual-socket SMP server, for application 
serving in Web environments

 

Please see the Legal Information section for important notices and information. 

18 

 
 
 
 

For More Information 

IBM System x and xSeries Servers 

 

 

       

ibm.com

/systems/x

 

Electronic Service Agent 

 

 

 

       

ibm.com

/support/electronic 

IBM System x and BladeCenter Power Configurator 

       

ibm.com

/systems/bladecenter/powerconfig 

Standalone Solutions Configuration Tool  

 

       

ibm.com

/servers/eserver/xseries/library/configtools.html 

Configuration and Options Guide  

 

 

       

ibm.com

/servers/eserver/xseries/cog  

ServerProven Program 

 

 

 

       

ibm.co

m/servers/eserver/serverproven/compat/us 

Technical Support 

 

 

 

       

ibm.com

/server/support 

Other Technical Support Resources 

 

 

       

ibm.com

/servers/eserver/techsupport.html

 

Legal Information 

© IBM Corporation 2008 

IBM Systems and Technology Group 
Dept. U2SA 
3039 Cornwallis Road 
Research Triangle Park, NC 27709 

Produced in the USA 
March 2008 

All rights reserved 

For a copy of applicable product warranties, write to: Warranty 
Information, P.O. Box 12195, RTP, NC 27709, Attn: Dept. 
JDJA/B203. IBM makes no representation or warranty 
regarding third-party products or services including those 
designated as ServerProven or ClusterProven. Telephone 
support may be subject to additional charges. For onsite labor, 
IBM will attempt to diagnose and resolve the problem remotely 
before sending a technician. 

IBM, the IBM logo, the e-business logo, Active Memory, 
Chipkill, iSeries, Predictive Failure Analysis, ServeRAID, 
System i, System Storage, System x, TotalStorage, xSeries 
and Xtended Design Architecture are trademarks of IBM 
Corporation in the United States and/or other countries. For a 
list of additional IBM trademarks, please see 
http://

ibm.com

/legal/copytrade.shtml. 

Linux is a registered trademark of Linus Torvalds. 

Microsoft, Windows and the Windows logo are trademarks or 
registered trademarks of Microsoft Corporation. 

Other company, product and service names may be 
trademarks or service marks of others. 

IBM reserves the right to change specifications or other 
product information without notice. References in this 
publication to IBM products or services do not imply that IBM 
intends to make them available in all countries in which IBM 
operates. IBM PROVIDES THIS PUBLICATION “AS IS” 
WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS 
OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR 
PURPOSE. Some jurisdictions do not allow disclaimer of 
express or implied warranties in certain transactions; 
therefore, this statement may not apply to you. 

This publication may contain links to third party sites that are 
not under the control of or maintained by IBM. Access to any 
such third party site is at the user's own risk and IBM is not 
responsible for the accuracy or reliability of any information, 
data, opinions, advice or statements made on these sites. IBM 
provides these links merely as a convenience and the 
inclusion of such links does not imply an endorsement. 

Information in this presentation concerning non-IBM products 
was obtained from the suppliers of these products, published 
announcement material or other publicly available sources. 
IBM has not tested these products and cannot confirm the 
accuracy of performance, compatibility or any other claims 
related to non-IBM products. Questions on the capabilities of 
non-IBM products should be addressed to the suppliers of 
those products. 

MB, GB and TB = 1,000,000, 1,000,000,000 and 
1,000,000,000,000 bytes, respectively, when referring to 
storage capacity. Accessible capacity is less; up to 3GB is 
used in service partition. Actual storage capacity will vary 
based upon many factors and may be less than stated. 

Performance is in Internal Throughput Rate (ITR) ratio based 
on measurements and projections using standard IBM 
benchmarks in a controlled environment. The actual 
throughput that any user will experience will depend on 
considerations such as the amount of multiprogramming in the 
user’s job stream, the I/O configuration, the storage 
configuration and the workload processed. Therefore, no 
assurance can be given that an individual user will achieve 
throughput improvements equivalent to the performance ratios 
stated here. 

Maximum internal hard disk and memory capacities may 
require the replacement of any standard hard drives and/or 
memory and the population of all hard disk bays and memory 
slots with the largest currently supported drives available. 
When referring to variable speed CD-ROMs, CD-Rs, CD-RWs 
and DVDs, actual playback speed will vary and is often less 
than the maximum possible.

 

 

Содержание x3650 - System M2 - 7947

Страница 1: ...al hard disk and backup drive configurations up to six 3 5 inch Serial Attach SCSI SAS hot swap drives with an internal storage capacity of 1 8TB1 or up to six 3 5 inch Serial ATA SATA hot swap drives...

Страница 2: ...d dual Gigabit Ethernet controllers with IPMI 2 0 support provide high speed network communications Jumbo Frames offer higher efficiency transfers for large data packets The TCP Offload Engine TOE fea...

Страница 3: ...s can help reduce downtime caused by memory errors Fully buffered DIMMs provide additional availability features including CRC cyclic redundancy check monitoring The x3650 offers selectable online hot...

Страница 4: ...ame speed Xeon processor with a single core Likewise quad core processors offer considerably higher performance than a same speed Xeon processor with dual cores Intel Extended Memory 64 Technology EM6...

Страница 5: ...x8 adapters Slot 1 is full length full height and Slot 2 is half length full height Electrically they are x8 slots as well meaning that they operate at full x8 4GBps speeds Slots 3 and 4 are low profi...

Страница 6: ...128MB battery backed cache 133MHz PCI X 2 ports for external SCSI RAID storage The ServeRAID 6M controllers support external SCSI expansion via the IBM EXP400 Storage Expansion Unit For external stor...

Страница 7: ...reds in a data center and it can make a big difference In addition the server uses hexagonal ventilation holes in the chassis Hexagonal holes can be grouped more densely than round holes providing gre...

Страница 8: ...es exiting each server which then connect to a KVM switch The cables exiting a series of KVM switches must then be aggregated via additional KVM switches and PDUs which only increases the number and c...

Страница 9: ...a highly secure electronic dialogue between your systems and IBM It monitors networked servers for hardware errors and it can perform hardware and software inventories and report inventory changes to...

Страница 10: ...unable to reset the hardware timer If the timer is not reset within five minutes it automatically triggers the ASR hardware which immediately restarts the server and logs an ASR event with IBM Directo...

Страница 11: ...are available Power Supply The optional second power supply for the x3650 enables redundancy for hot swap power and adds five additional fans for increased cooling capacity and redundancy Remote Super...

Страница 12: ...ntralize your Microsoft Windows and System i5 or iSeries storage and consolidate the operations and backup of your System x xSeries System i5 and iSeries systems into a single infrastructure It enable...

Страница 13: ...JAX JAY 1 86GHz L5320 JBX JBY Dual core Xeon 51xx 1 6GHz E5110 2xX 2xY 2 0GHz E5130 4xX 4xY 2 33GHz E5140 5xX 5xY 3 0GHz E5160 7xX 7xY Maximum processor power draw 50W JxX JxY LxX LxY 65W 2xX 2xY 4xX...

Страница 14: ...0GB hot swap SAS with internal backup drive installed x1X x1Y L2X L2Y x3X x3Y x4X x4Y x7X x7Y x9X x9Y 2 5 inch SAS 1 17TB 8 x 146 8GB hot swap SAS with or without internal backup drive xAX xAY xBX xBY...

Страница 15: ...one USB attached of keyboard ports None USB attached of USB 2 0 ports 6 external 2 front 4 rear ports plus 1 internal USB connector Integrated systems management controller Yes BMC Optional systems ma...

Страница 16: ...apacity 48GB of fully buffered memory using 12 DIMMs A choice of six 3 5 inch SAS or SATA drives or eight 2 5 inch SAS drives High capacity disk storage Up to 1 8TB of internal hot swap SAS or 6TB of...

Страница 17: ...memory protection and either Online hot spare memory or Memory mirroring Slotless hardware based RAID 1 disk mirroring and RAID 10 striped mirrored arrays standard optional slotless RAID 1E 5 6 highl...

Страница 18: ...ble in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FO...

Отзывы: