background image

A highly available and expandable, rack-dense, 2U dual-socket SMP server, for application 
serving in Web environments

 

Please see the Legal Information section for important notices and information. 

 

Manageability 

Powerful systems management features simplify local and remote management of the x3650:  

  The x3650 includes a 

Baseboard Management Controller (BMC)

 to monitor server 

availability, perform Predictive Failure Analysis, etc., and trigger IBM Director alerts. The 
BMC enables service personnel to use sophisticated diagnostic tools, such as light path 
diagnostics, to resolve problems quickly. 

  Integrated 

IPMI 2.0

 support alerts IBM Director to anomalous environmental factors, such as 

voltage and thermal conditions. It also supports 

highly secure remote power control

 using 

data encryption. 

  IBM

 Systems Director Active Energy Manager for x86

, an IBM-exclusive, is designed to 

take advantage of new system power management features, by providing power monitoring 
today, and power capping features later.

 

 

 

Text Console Redirection 

support allows the administrator to remotely view x3650 text 

messages over Serial or LAN. 

 

IBM

 

Director 

is included for proactive systems management and works with both the blade’s 

internal BMC and the chassis’ management module. IBM Director comes with a portfolio of 
tools, including 

Management Processor Assistant, Rack Manager, RAID Manager, Update 

Assistant

 and 

Software Distribution

. In addition, IBM Director offers extended systems 

management tools for additional server management and increased availability. When a 
problem is encountered, IBM Director can issue administrator alerts via e-mail, pager, and 
other methods.  

  An optional 

Remote Supervisor Adapter II SlimLine

 provides additional systems 

management capabilities, including 

Web-based out-of-band control; virtual floppy and optical 

drive support; Windows “blue screen” error capture; LDAP and SSL support; 

and

 remote 

redirection of PCI video, text, keyboard and mouse

. It also adds 

PFA support for fans

. And it 

does all this without consuming a valuable adapter slot. 

 

Availability and Serviceability 

The x3650 provides many features to simplify serviceability and increase system uptime:  

  x3650 servers use 

fully buffered DDR II 

DIMMs with Chipkill protection. Chipkill memory is 

up to 

16X

 better than standard ECC memory at correcting memory errors. This can help 

reduce downtime caused by memory errors. 

Fully buffered DIMMs

 provide additional 

availability features, including CRC (cyclic redundancy check) monitoring. 

  The x3650 offers selectable 

online hot-spare memory

 and 

memory mirroring

 for 

redundancy in the event of a noncorrectable memory failure. 

 

Toolless

 

cover removal

 provides easy access to upgrades and serviceable parts. Similarly, 

the 

Remote Supervisor Adapter II SlimLine

 and the 

ServeRAID-8k

 controller can be 

installed and replaced without tools. This means less time (and therefore less money) spent 
servicing the server. Also, 

hot-swap/redundant HDDs, fans

 and 

power supplies

, as well 

as 

online hot-spare

 and 

mirrored

 memory, can mean greater system uptime while 

components are being serviced. 

  The 

drop-down light path diagnostics panel

 and individual light path LEDs quickly lead 

the technician to failed (or failing) components. This simplifies servicing, speeds up problem 
resolution and helps improve network availability. 

 

Integrated RAID-1 disk mirroring

 and 

RAID-10 striped mirrored arrays

 enable the server 

to keep operating in the event of a failure to any one drive. 

 

IPMI 2.0

 supports highly secure remote system power control using data encryption. This 

allows an administrator to restart a server without having to visit it in person, saving travel 
time and getting the server back up and running quickly and securely. It also adds new 
features to those provided by IPMI 1.5, including 

VLAN

 support, 

Serial over LAN,

 enhanced 

authentication and encryption algorithms (

RMCP+, SHA-1, AES

) and a 

firmware firewall

 

Temperature-controlled fans

 adjust to compensate for changing thermal characteristics. At 

the lower speeds they draw less power and suffer less wear. Equally important in a crowded 
data center, temperature-controlled fans produce less ambient noise in the data center than 
if they were constantly running at full speed. 

  IBM 

Thermal Diagnostics

 allows the administrator to evaluate thermal data on the server 

without taking the hardware offline. This can provide greater server uptime. 

 

The

 three-year (parts and labor) limited onsite warranty

3

 affords you peace of mind and 

3

 For terms and conditions or copies of the IBM Statement of Limited Warranty, call 800-772-2227 in the U.S. In Canada call 800-

426-2255. Telephone support may be subject to additional charges. For warranties including onsite labor, a technician is sent after 
IBM attempts to resolve the problem remotely. International warranty service is available in any country in which this product is 
sold. 

Содержание x3650 - System M2 - 7947

Страница 1: ...al hard disk and backup drive configurations up to six 3 5 inch Serial Attach SCSI SAS hot swap drives with an internal storage capacity of 1 8TB1 or up to six 3 5 inch Serial ATA SATA hot swap drives...

Страница 2: ...d dual Gigabit Ethernet controllers with IPMI 2 0 support provide high speed network communications Jumbo Frames offer higher efficiency transfers for large data packets The TCP Offload Engine TOE fea...

Страница 3: ...s can help reduce downtime caused by memory errors Fully buffered DIMMs provide additional availability features including CRC cyclic redundancy check monitoring The x3650 offers selectable online hot...

Страница 4: ...ame speed Xeon processor with a single core Likewise quad core processors offer considerably higher performance than a same speed Xeon processor with dual cores Intel Extended Memory 64 Technology EM6...

Страница 5: ...x8 adapters Slot 1 is full length full height and Slot 2 is half length full height Electrically they are x8 slots as well meaning that they operate at full x8 4GBps speeds Slots 3 and 4 are low profi...

Страница 6: ...128MB battery backed cache 133MHz PCI X 2 ports for external SCSI RAID storage The ServeRAID 6M controllers support external SCSI expansion via the IBM EXP400 Storage Expansion Unit For external stor...

Страница 7: ...reds in a data center and it can make a big difference In addition the server uses hexagonal ventilation holes in the chassis Hexagonal holes can be grouped more densely than round holes providing gre...

Страница 8: ...es exiting each server which then connect to a KVM switch The cables exiting a series of KVM switches must then be aggregated via additional KVM switches and PDUs which only increases the number and c...

Страница 9: ...a highly secure electronic dialogue between your systems and IBM It monitors networked servers for hardware errors and it can perform hardware and software inventories and report inventory changes to...

Страница 10: ...unable to reset the hardware timer If the timer is not reset within five minutes it automatically triggers the ASR hardware which immediately restarts the server and logs an ASR event with IBM Directo...

Страница 11: ...are available Power Supply The optional second power supply for the x3650 enables redundancy for hot swap power and adds five additional fans for increased cooling capacity and redundancy Remote Super...

Страница 12: ...ntralize your Microsoft Windows and System i5 or iSeries storage and consolidate the operations and backup of your System x xSeries System i5 and iSeries systems into a single infrastructure It enable...

Страница 13: ...JAX JAY 1 86GHz L5320 JBX JBY Dual core Xeon 51xx 1 6GHz E5110 2xX 2xY 2 0GHz E5130 4xX 4xY 2 33GHz E5140 5xX 5xY 3 0GHz E5160 7xX 7xY Maximum processor power draw 50W JxX JxY LxX LxY 65W 2xX 2xY 4xX...

Страница 14: ...0GB hot swap SAS with internal backup drive installed x1X x1Y L2X L2Y x3X x3Y x4X x4Y x7X x7Y x9X x9Y 2 5 inch SAS 1 17TB 8 x 146 8GB hot swap SAS with or without internal backup drive xAX xAY xBX xBY...

Страница 15: ...one USB attached of keyboard ports None USB attached of USB 2 0 ports 6 external 2 front 4 rear ports plus 1 internal USB connector Integrated systems management controller Yes BMC Optional systems ma...

Страница 16: ...apacity 48GB of fully buffered memory using 12 DIMMs A choice of six 3 5 inch SAS or SATA drives or eight 2 5 inch SAS drives High capacity disk storage Up to 1 8TB of internal hot swap SAS or 6TB of...

Страница 17: ...memory protection and either Online hot spare memory or Memory mirroring Slotless hardware based RAID 1 disk mirroring and RAID 10 striped mirrored arrays standard optional slotless RAID 1E 5 6 highl...

Страница 18: ...ble in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FO...

Отзывы: