A highly available and expandable, rack-dense, 2U dual-socket SMP server, for application 
serving in Web environments

 

Please see the Legal Information section for important notices and information. 

 

Dual Gigabit Ethernet Controllers 

The x3650 includes 

two

 integrated 

Broadcom BCM5708 

Gigabit Ethernet controllers with

 TOE

 

support, as well as 

load-balancing

 and 

failover

 capabilities, with up to 10X higher maximum 

throughput than a 10/100 Ethernet controller. 

TOE

 helps improve overall system performance by offloading TCP/IP protocol processing from 

the system microprocessor to the onboard Ethernet TOE processor. 

The controllers also support highly secure remote power management using 

IPMI

 

2.0

, plus 

Wake on LAN

®

 and 

PXE

 (Preboot Execution Environment) flash interface. Optional PCI 

adapters offering failover and load balancing between adapters are available for added 
throughput and increased system availability. 

 

Ultra-Efficient Cooling 

Strategically located fans, combined with efficient airflow paths, provide highly effective system 
cooling for the x3650, known as 

Calibrated Vectored Cooling

. The base server with one power 

supply includes 

five

 fans. 

Five

 additional 

hot-swap fans

 can be installed along with the 

redundant power supply.  

The system contains 

four cooling zones

Zone 1

 (incorporating one fan in a nonredundant 

configuration or two with redundancy) cools one processor. 

Zone 2

 (one or two fans) cools the 

other processor, 

Zone 3

 (one or two fans) cools the adapter slots and memory, and 

Zone 4

 (two 

or four fans) cools the HDDs, power supplies and system backplane. In addition, each power 
supply also contains a fan. 

The fans automatically adjust speeds in response to changing thermal requirements, from a 
minimum of 

4,250

 RPMs to a maximum of 

8,000

 RPMs, depending on the zone, redundancy, 

and internal temperatures. When the temperature inside the server increases, the fans speed up 
to maintain the proper ambient temperature. When the temperature returns to a normal 
operating level, the fans return to their default speed. Why not simply run the fans at 100% 
capacity all the time? For several good reasons: to reduce the ambient noise, reduce the wear-
and-tear on the fans and reduce the server power draw. The reduction in ambient noise and 
power draw may be relatively minor for a single server, but put dozens or hundreds in a data 
center and it can make a big difference! 

In addition, the server uses 

hexagonal ventilation holes

 in the chassis. Hexagonal holes can 

be grouped more densely than round holes, providing greater airflow through the system cover. 

This cooling scheme is important because newer, more powerful processors generate a 
significant amount of heat, and heat must be controlled for the system to function properly. 

 

Light Path Diagnostics 

Light path diagnostics enables a technician to quickly identify and locate a failed or failing 
system component, such as a specific fan or memory DIMM. This enables quick replacement of 
the component, which helps increase server uptime and lower operating costs.  

The front of the server has an LED indicator light to show possible component failures. If the 
front LED indicates an error condition, by pressing a button on the front of the server an LED 
panel will pop out and drop down for easy viewing without the need to open the server cover or 
remove the server from the rack. The light path diagnostics panel tells the servicer which 
component requires attention. In addition, many components have their own identifying LEDs. 
For example, each of the eight memory modules has an LED next to the socket, as do both 
processors, all adapter slots, all fans, all power supplies, the voltage regulator module and the 
service processor, allowing the servicer to easily identify exactly which component needs 
servicing. By following the “light path,” the component can be replaced quickly, and without 
guesswork. (

Note:

 In the event of a failed DIMM, the system will restart and mark the DIMM as 

bad while offline, thus allowing the system to continue running, with reduced memory capacity, 
until serviced.) 

 

Other Features 

 

Seven USB 2.0 ports

 — Provides flexibility to add high-speed external devices. The USB 

2.0 specification supports up to 480Mbps transfer rates. (Note: Not all USB 2.0 devices are 
capable of achieving this rate.) Two ports are provided on the front of the server, four are on 
the back, and one is internal to support a USB-interface tape or GoVault EZ backup drive. 

 

Remote Supervisor Adapter II SlimLine support

 — This optional full-function systems 

management adapter adds local and remote management functions without consuming an 
adapter slot. 

 

Internal SATA port 

— Provides easy connection of 

internal SATA-based backup

 storage 

 

Dual video ports

 — An 

ATI Radeon ES1000

 SVGA video controller provides up to 

1024x768

 resolution, with a color depth of 

32

 bits at 

85Hz

 refresh rate. To simplify local 

Содержание x3650 - System M2 - 7947

Страница 1: ...al hard disk and backup drive configurations up to six 3 5 inch Serial Attach SCSI SAS hot swap drives with an internal storage capacity of 1 8TB1 or up to six 3 5 inch Serial ATA SATA hot swap drives...

Страница 2: ...d dual Gigabit Ethernet controllers with IPMI 2 0 support provide high speed network communications Jumbo Frames offer higher efficiency transfers for large data packets The TCP Offload Engine TOE fea...

Страница 3: ...s can help reduce downtime caused by memory errors Fully buffered DIMMs provide additional availability features including CRC cyclic redundancy check monitoring The x3650 offers selectable online hot...

Страница 4: ...ame speed Xeon processor with a single core Likewise quad core processors offer considerably higher performance than a same speed Xeon processor with dual cores Intel Extended Memory 64 Technology EM6...

Страница 5: ...x8 adapters Slot 1 is full length full height and Slot 2 is half length full height Electrically they are x8 slots as well meaning that they operate at full x8 4GBps speeds Slots 3 and 4 are low profi...

Страница 6: ...128MB battery backed cache 133MHz PCI X 2 ports for external SCSI RAID storage The ServeRAID 6M controllers support external SCSI expansion via the IBM EXP400 Storage Expansion Unit For external stor...

Страница 7: ...reds in a data center and it can make a big difference In addition the server uses hexagonal ventilation holes in the chassis Hexagonal holes can be grouped more densely than round holes providing gre...

Страница 8: ...es exiting each server which then connect to a KVM switch The cables exiting a series of KVM switches must then be aggregated via additional KVM switches and PDUs which only increases the number and c...

Страница 9: ...a highly secure electronic dialogue between your systems and IBM It monitors networked servers for hardware errors and it can perform hardware and software inventories and report inventory changes to...

Страница 10: ...unable to reset the hardware timer If the timer is not reset within five minutes it automatically triggers the ASR hardware which immediately restarts the server and logs an ASR event with IBM Directo...

Страница 11: ...are available Power Supply The optional second power supply for the x3650 enables redundancy for hot swap power and adds five additional fans for increased cooling capacity and redundancy Remote Super...

Страница 12: ...ntralize your Microsoft Windows and System i5 or iSeries storage and consolidate the operations and backup of your System x xSeries System i5 and iSeries systems into a single infrastructure It enable...

Страница 13: ...JAX JAY 1 86GHz L5320 JBX JBY Dual core Xeon 51xx 1 6GHz E5110 2xX 2xY 2 0GHz E5130 4xX 4xY 2 33GHz E5140 5xX 5xY 3 0GHz E5160 7xX 7xY Maximum processor power draw 50W JxX JxY LxX LxY 65W 2xX 2xY 4xX...

Страница 14: ...0GB hot swap SAS with internal backup drive installed x1X x1Y L2X L2Y x3X x3Y x4X x4Y x7X x7Y x9X x9Y 2 5 inch SAS 1 17TB 8 x 146 8GB hot swap SAS with or without internal backup drive xAX xAY xBX xBY...

Страница 15: ...one USB attached of keyboard ports None USB attached of USB 2 0 ports 6 external 2 front 4 rear ports plus 1 internal USB connector Integrated systems management controller Yes BMC Optional systems ma...

Страница 16: ...apacity 48GB of fully buffered memory using 12 DIMMs A choice of six 3 5 inch SAS or SATA drives or eight 2 5 inch SAS drives High capacity disk storage Up to 1 8TB of internal hot swap SAS or 6TB of...

Страница 17: ...memory protection and either Online hot spare memory or Memory mirroring Slotless hardware based RAID 1 disk mirroring and RAID 10 striped mirrored arrays standard optional slotless RAID 1E 5 6 highl...

Страница 18: ...ble in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FO...

Отзывы: