background image

A highly available and expandable, rack-dense, 2U dual-socket SMP server, for application 
serving in Web environments

 

Please see the Legal Information section for important notices and information. 

10 

  Local update of BMC firmware 

  Firmware firewall 

  Support for IPMI v2.0 compliant management software (e.g., xCAT) 

  Other mandatory and optional IPMI BMC functions 

The BMC alerts IBM Director to anomalous environmental factors, such as voltage and thermal 
conditions—even if the server has failed. 

The x3650 also supports an optional IBM 

Remote Supervisor Adapter

 

II SlimLine

 for 

additional systems management capabilities, including: 

  Predictive Failure Analysis for system fans 

  Graphical console redirection over LAN 

  Web-based out-of-band control 

  Windows “blue screen” capture 

  Remote virtual floppy and CD-ROM 

  High-speed remote redirection of PCI video, keyboard and mouse 

  SSL (Secure Socket Layer) and LDAP (Lightweight Directory Access Protocol) support 

IBM developed IBM 

Systems Director Active Energy Manager for x86

 to put control of 

system power-saving features at the fingertips of administrators. 

Active Energy Manager

 is 

designed to take advantage of new features, such as monitoring power usage and balancing the 
performance of the system according to available power input. It provides the ability to plan and 
predict power consumption based on your hardware configuration. It also helps enable you to 
reduce the infrastructure required for redundancy, by using fewer servers on smaller power 
feeds and potentially lowering your overall data center support costs. It does this by inventorying 
all components, then adding up the total power draw and tracking the usage.  

Automatic Server Restart

 (ASR) helps reduce downtime by restarting the server automatically 

in the event of a system lockup. ASR technology is a combination of hardware circuitry tied into 
the server’s system reset function and a device driver. As long as the server continues running, 
the ASR watchdog timer will keep being reset, but if the operating system crashes or the 
hardware freezes somehow the ASR software will be unable to reset the hardware timer. If the 
timer is not reset within five minutes, it automatically triggers the ASR hardware, which 
immediately restarts the server (and logs an ASR event with IBM Director). These features are 
designed so that 

no more than five minutes can pass before the server is restarted

Wake on LAN

 permits the server to be remotely powered on if it has been shut off. Once 

powered up, the server can be controlled across the network, using the 

Preboot Execution 

Environment

 (PXE). 

Like Wake on LAN, PXE is system firmware. It enables software such as the optional 

IBM 

Remote Deployment Manager

 to take control of a system before the BIOS, operating system 

or applications are loaded (using Wake on LAN/PXE) and lets an administrator perform many 
low-level tasks remotely that would otherwise require a visit to each system. These tasks may 
include such things as formatting a hard disk drive, updating system firmware, or deploying a 
Windows or Linux operating system.  

Text Console Redirection 

support allows the administrator to remotely view x3650 text 

messages over serial or LAN. An upgrade to the optional 

Remote Supervisor Adapter II 

SlimLine

 adds graphical console redirect. 

Predictive Failure Analysis

 

(PFA)

 is designed to allow the x3650 to detect impending failure of 

supported components (processors, memory, voltage regulator modules (VRMs), power 
supplies and hard disk drives) 

before

 actual failure, and alert the administrator through IBM 

Director. This gives you the ability to replace the failing component 

before

 it fails, resulting in 

increased uptime. 

IBM Director 

software for advanced workgroup management is included with the x3650. IBM 

Director comes with a portfolio of tools, including 

Management Processor Assistant, Rack 

Manager, RAID Manager, Update Assistant and Software Distribution. IBM Systems Director 
Active Energy Manager for x86, System Availability 

(a no-charge download) and 

Capacity 

Manager

 (sold separately) are available as add-ons for additional server management and 

increased availability. IBM Director provides a single uniform graphical interface for all of these 
systems management functions. 

IBM Director enables you to customize thresholds and monitor system components (for things 
like temperature, voltage regulation, etc.) to help maximize uptime. 

Содержание x3650 - System M2 - 7947

Страница 1: ...al hard disk and backup drive configurations up to six 3 5 inch Serial Attach SCSI SAS hot swap drives with an internal storage capacity of 1 8TB1 or up to six 3 5 inch Serial ATA SATA hot swap drives...

Страница 2: ...d dual Gigabit Ethernet controllers with IPMI 2 0 support provide high speed network communications Jumbo Frames offer higher efficiency transfers for large data packets The TCP Offload Engine TOE fea...

Страница 3: ...s can help reduce downtime caused by memory errors Fully buffered DIMMs provide additional availability features including CRC cyclic redundancy check monitoring The x3650 offers selectable online hot...

Страница 4: ...ame speed Xeon processor with a single core Likewise quad core processors offer considerably higher performance than a same speed Xeon processor with dual cores Intel Extended Memory 64 Technology EM6...

Страница 5: ...x8 adapters Slot 1 is full length full height and Slot 2 is half length full height Electrically they are x8 slots as well meaning that they operate at full x8 4GBps speeds Slots 3 and 4 are low profi...

Страница 6: ...128MB battery backed cache 133MHz PCI X 2 ports for external SCSI RAID storage The ServeRAID 6M controllers support external SCSI expansion via the IBM EXP400 Storage Expansion Unit For external stor...

Страница 7: ...reds in a data center and it can make a big difference In addition the server uses hexagonal ventilation holes in the chassis Hexagonal holes can be grouped more densely than round holes providing gre...

Страница 8: ...es exiting each server which then connect to a KVM switch The cables exiting a series of KVM switches must then be aggregated via additional KVM switches and PDUs which only increases the number and c...

Страница 9: ...a highly secure electronic dialogue between your systems and IBM It monitors networked servers for hardware errors and it can perform hardware and software inventories and report inventory changes to...

Страница 10: ...unable to reset the hardware timer If the timer is not reset within five minutes it automatically triggers the ASR hardware which immediately restarts the server and logs an ASR event with IBM Directo...

Страница 11: ...are available Power Supply The optional second power supply for the x3650 enables redundancy for hot swap power and adds five additional fans for increased cooling capacity and redundancy Remote Super...

Страница 12: ...ntralize your Microsoft Windows and System i5 or iSeries storage and consolidate the operations and backup of your System x xSeries System i5 and iSeries systems into a single infrastructure It enable...

Страница 13: ...JAX JAY 1 86GHz L5320 JBX JBY Dual core Xeon 51xx 1 6GHz E5110 2xX 2xY 2 0GHz E5130 4xX 4xY 2 33GHz E5140 5xX 5xY 3 0GHz E5160 7xX 7xY Maximum processor power draw 50W JxX JxY LxX LxY 65W 2xX 2xY 4xX...

Страница 14: ...0GB hot swap SAS with internal backup drive installed x1X x1Y L2X L2Y x3X x3Y x4X x4Y x7X x7Y x9X x9Y 2 5 inch SAS 1 17TB 8 x 146 8GB hot swap SAS with or without internal backup drive xAX xAY xBX xBY...

Страница 15: ...one USB attached of keyboard ports None USB attached of USB 2 0 ports 6 external 2 front 4 rear ports plus 1 internal USB connector Integrated systems management controller Yes BMC Optional systems ma...

Страница 16: ...apacity 48GB of fully buffered memory using 12 DIMMs A choice of six 3 5 inch SAS or SATA drives or eight 2 5 inch SAS drives High capacity disk storage Up to 1 8TB of internal hot swap SAS or 6TB of...

Страница 17: ...memory protection and either Online hot spare memory or Memory mirroring Slotless hardware based RAID 1 disk mirroring and RAID 10 striped mirrored arrays standard optional slotless RAID 1E 5 6 highl...

Страница 18: ...ble in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FO...