background image

A highly available and expandable, rack-dense, 2U dual-socket SMP server, for application 
serving in Web environments

 

Please see the Legal Information section for important notices and information. 

updated frequently to ensure that the latest compatibility information is always at your fingertips. 

The IBM 

Standalone Solutions Configuration Tool 

(SSCT) is a downloadable tool that 

simplifies the often complex chore of configuring a full rack of servers (including blade servers) 
and confirming that you have all the cables, power distribution units, KVM (keyboard, video and 
mouse) switch boxes and other components you need, as well as the proper airflow clearances, 
electrical circuits and other environmental conditions. 

IBM

 System x and BladeCenter Power Configurator

 helps IT managers plan for data center 

power needs, by providing the following information for specific configurations of System x and 
BladeCenter systems: 

power input

 (watts), 

PDU sizing

 (amps), 

heat output

 (BTUs), 

airflow 

requirements through chassis

 (CFM), 

VA rating

leakage current

 (mA), and 

peak inrush current

 

(amps). 

IBM 

ServerGuide

 (installed from CD) simplifies the process of installing and configuring System 

x and xSeries servers. ServerGuide goes beyond mere hardware configuration by assisting with 
the automated installation of the Microsoft

®

 Windows

®

 Server 2000 and 2003 operating 

systems, device drivers and other system components, with minimal user intervention. (Drivers 
are also included for support of Novell NetWare, Red Hat Linux and SUSE LINUX.) This focus 
on deployment helps you reduce both your total cost of ownership and the complexity that 
administrators and technical personnel face. 

IBM 

Electronic Service Agent

 is an innovative “call home” feature that allows System x and 

BladeCenter servers to automatically report hardware problems to IBM support, which can even 
dispatch onsite service

7

 if necessary to those customers entitled to onsite support under the 

terms of their warranty or an IBM Maintenance Agreement. Electronic Service Agent resides on 
a server and provides electronic support and problem management capabilities through a highly 
secure electronic dialogue between your systems and IBM. It monitors networked servers for 
hardware errors and it can perform hardware and software inventories and report inventory 
changes to IBM. All information sent to IBM is stored in a highly secure database and used for 
improved problem determination. 

Additional services include hardware warranty upgrades and factory-installed 

Product 

Customization Services

 (PCS), such as asset tagging, hardware integration, software imaging 

and operating systems personalization. 

IBM offers extensive 

technical support

 by phone and via the Web. Support options include 

links to forums/newsgroups, problem submission, online shopping support, service offerings, 
device drivers for all IBM product lines, software downloads and even upcoming technical 
seminar worldwide schedules and registration. Also available are remote installation, 
configuration and usage support for System x and xSeries hardware and software, as well as 
onsite custom services to provide the level of expertise you require. 

 

Advanced Systems Management Capabilities 

The x3650 has a high level of systems management capabilities that are well-suited to remote 
locations as well as to stand-alone environments. Features include the Baseboard Management 
Controller

 (BMC),

 IBM Systems Director Active Energy Manager for x86, Automatic Server 

Restart, Wake on LAN

®

 support, PXE support, text console redirect, Predictive Failure Analysis, 

IBM Director and support for an optional Remote Supervisor Adapter II SlimLine. 

The BMC provides industry-standard 

Intelligent Platform Management Interface

 (

IPMI

2.0

-

compliant systems management. It provides a number of important system functions, including: 

  Monitoring of system and battery voltage, system temperature, fans, power supplies, 

processor and DIMM status 

  Fan speed control 

  Product ID and Family ID detection 

  Highly secure remote power on/off 

  System reset control 

  NMI/SMI detection and generation 

  System diagnostic LED control (power, HDD, activity, alerts, heartbeat) 

  IPMI over LAN 

  Serial Over LAN 

  Proxy server support 

  LAN messaging and alerting 

  Text console redirection over LAN 

  VLAN support 

  Enhanced authentication and encryption algorithms (RMCP+, SHA-1, AES) 

7

 For onsite labor, IBM will attempt to diagnose and resolve the problem remotely before sending a technician.

 

Содержание x3650 - System M2 - 7947

Страница 1: ...al hard disk and backup drive configurations up to six 3 5 inch Serial Attach SCSI SAS hot swap drives with an internal storage capacity of 1 8TB1 or up to six 3 5 inch Serial ATA SATA hot swap drives...

Страница 2: ...d dual Gigabit Ethernet controllers with IPMI 2 0 support provide high speed network communications Jumbo Frames offer higher efficiency transfers for large data packets The TCP Offload Engine TOE fea...

Страница 3: ...s can help reduce downtime caused by memory errors Fully buffered DIMMs provide additional availability features including CRC cyclic redundancy check monitoring The x3650 offers selectable online hot...

Страница 4: ...ame speed Xeon processor with a single core Likewise quad core processors offer considerably higher performance than a same speed Xeon processor with dual cores Intel Extended Memory 64 Technology EM6...

Страница 5: ...x8 adapters Slot 1 is full length full height and Slot 2 is half length full height Electrically they are x8 slots as well meaning that they operate at full x8 4GBps speeds Slots 3 and 4 are low profi...

Страница 6: ...128MB battery backed cache 133MHz PCI X 2 ports for external SCSI RAID storage The ServeRAID 6M controllers support external SCSI expansion via the IBM EXP400 Storage Expansion Unit For external stor...

Страница 7: ...reds in a data center and it can make a big difference In addition the server uses hexagonal ventilation holes in the chassis Hexagonal holes can be grouped more densely than round holes providing gre...

Страница 8: ...es exiting each server which then connect to a KVM switch The cables exiting a series of KVM switches must then be aggregated via additional KVM switches and PDUs which only increases the number and c...

Страница 9: ...a highly secure electronic dialogue between your systems and IBM It monitors networked servers for hardware errors and it can perform hardware and software inventories and report inventory changes to...

Страница 10: ...unable to reset the hardware timer If the timer is not reset within five minutes it automatically triggers the ASR hardware which immediately restarts the server and logs an ASR event with IBM Directo...

Страница 11: ...are available Power Supply The optional second power supply for the x3650 enables redundancy for hot swap power and adds five additional fans for increased cooling capacity and redundancy Remote Super...

Страница 12: ...ntralize your Microsoft Windows and System i5 or iSeries storage and consolidate the operations and backup of your System x xSeries System i5 and iSeries systems into a single infrastructure It enable...

Страница 13: ...JAX JAY 1 86GHz L5320 JBX JBY Dual core Xeon 51xx 1 6GHz E5110 2xX 2xY 2 0GHz E5130 4xX 4xY 2 33GHz E5140 5xX 5xY 3 0GHz E5160 7xX 7xY Maximum processor power draw 50W JxX JxY LxX LxY 65W 2xX 2xY 4xX...

Страница 14: ...0GB hot swap SAS with internal backup drive installed x1X x1Y L2X L2Y x3X x3Y x4X x4Y x7X x7Y x9X x9Y 2 5 inch SAS 1 17TB 8 x 146 8GB hot swap SAS with or without internal backup drive xAX xAY xBX xBY...

Страница 15: ...one USB attached of keyboard ports None USB attached of USB 2 0 ports 6 external 2 front 4 rear ports plus 1 internal USB connector Integrated systems management controller Yes BMC Optional systems ma...

Страница 16: ...apacity 48GB of fully buffered memory using 12 DIMMs A choice of six 3 5 inch SAS or SATA drives or eight 2 5 inch SAS drives High capacity disk storage Up to 1 8TB of internal hot swap SAS or 6TB of...

Страница 17: ...memory protection and either Online hot spare memory or Memory mirroring Slotless hardware based RAID 1 disk mirroring and RAID 10 striped mirrored arrays standard optional slotless RAID 1E 5 6 highl...

Страница 18: ...ble in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FO...

Отзывы: