background image

4

 

 1:  I

NSTALLATION

 

Introduction 

The 

IBM

®

 UPS 7500XHV and UPS 10000XHV 

models are high-performance uninterruptible power supplies, designed to pre-

vent blackouts, brownouts, sags, and surges from reaching your computer and other sensitive electronic equipment. The uninter-
ruptible power supply filters small utility line fluctuations and isolates your equipment from large disturbances by internally 
disconnecting from the utility line. The uninterruptible power supply provides continuous power from its internal battery until 
the utility line returns to safe levels or the battery is fully discharged. 

Unpacking 

Attention: 

 

 

Read the Safety Instructions in this documentation before you install the uninterruptible power supply.  

 

The uninterruptible power supply comes with its battery disconnected. 

Note: 

The illustrations in this documentation might differ slightly from your hardware. 

Inspect the uninterruptible power supply upon receipt. Accidents and damage can occur during shipment. Notify the carrier and 
your IBM marketing representative or authorized reseller if there is damage. 

The packaging is recyclable; save it for reuse or dispose of it properly. 

Check the package contents: 

 

Uninterruptible power supply 

 

Two front bezels 

 

Rail kit 

 

Tower conversion kit 

 

Accessory kit containing: 

 

Quick Installation Guide 

 

Documentation CD 

 

PowerChute

® 

Business Edition CD 

 

Network Management Card CD 

 

Warranty Flyer 

 

Rack-mounting brackets 

 

Temperature probe  

 

Serial communication cable – 4.6 m (15 ft) 

 

Serial to USB adapter cable – 2 m (6.5 ft) 

 

Four output power cables – 2 m (6.5 ft) 

You will need the following tools to install the uninterruptible power supply:  

 

Utility knife or scissors 

 

Two Philips screwdrivers (#1 and #2) 

 

Two wrenches (.438” and .250”) 

 

Cage-nut-insertion tool or flat-blade screwdriver (for installing cage-nuts in some rack cabinets) 

Removing the Battery Modules 

The uninterruptible power supply is heavy. To lighten the weight of the unit, remove the battery modules. 

 

Remove the battery doors. 

 

Remove all battery modules. 

Note: 

Write down the MAC address from under the uninter-

ruptible power supply.

 

 

 

Содержание UPS 7500XHV

Страница 1: ...IBM UPS 7500XHV IBM UPS 10000XHV Uninterruptible Power Supply Operation and Setup Guide 25R5636...

Страница 2: ......

Страница 3: ...e 12 Battery Runtime Tables 12 3 USER CONFIGURABLE ITEMS 14 Emergency Power Off EPO Option 15 4 STORAGE MAINTENANCE SHIPPING AND SERVICE 16 Storage 16 Replacing the Battery Modules 16 Replacing the Ne...

Страница 4: ......

Страница 5: ...r dette produkt Lees voordat u dit product installeert eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lise...

Страница 6: ...you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling ADVERTENCIA El contacto con el cable de este producto o c...

Страница 7: ...m the utility power outlet before installing or connecting to other equipment Reconnect the power only after all connections are made Do not handle any metallic connector before the power has been dis...

Страница 8: ...ents and damage can occur during shipment Notify the carrier and your IBM marketing representative or authorized reseller if there is damage The packaging is recyclable save it for reuse or dispose of...

Страница 9: ...trician 1 Install a utility circuit breaker according to local electrical codes see tables below for input wiring Input Connections Output Connection optional Single Phase Wire to L1 N and Three Phase...

Страница 10: ...hardwired input and output power cables 7 For three phase input set the Input Phase Selector switch see C in the diagram to 3 For single phase input leave the switch in the default position of 1 8 Sw...

Страница 11: ...ling and Connecting the Batteries and Attaching the Front Battery Bezel Install all battery modules Connect the batteries Reinstall and secure the battery doors with the captive screws Make sure the c...

Страница 12: ...on and remove the display bezel by sliding to the left and out Rotate the display bezel and reinstall Install the first battery module at the bottom Reinstall the remaining three battery modules Conne...

Страница 13: ...m extreme overloads when in the on position The breaker must be on for the unit to operate 8 Ethernet Port Network Management Card Connect the uninterruptible power supply to the network 9 Battery Pac...

Страница 14: ...s played Click OK b Select the COM port that is connected to your uninterruptible power supply The port settings are bits per second 2400 data bits 8 parity none stop bit 1 flow control none c Click E...

Страница 15: ...verload This LED is lit and the uninterruptible power supply emits a sustained alarm tone when the connected loads are drawing more than the uninterruptible power supply power rating See Troubleshooti...

Страница 16: ...extremely high and should be checked by an electrician On Battery Operation The uninterruptible power supply automatically switches to battery operation if the utility power fails While running on ba...

Страница 17: ...1 65 4000 13 28 46 1 36 5000 10 21 35 1 06 6000 7 16 28 52 Recharge Hours 3 7 10 17 UPS 10000XHV Model Number of Battery Packs Load W Internal 1 2 4 50 7 56 13 83 21 55 37 68 100 6 00 10 93 17 06 29...

Страница 18: ...e all existing alarms permanently Shutdown Delay 20 seconds 0 20 60 120 240 480 720 960 sec onds The interval is set between the times when the uninterruptible power supply receives a shutdown command...

Страница 19: ...he switch is powered by a 12 V internal power supply A closed switch draws 2 mA of current The EPO switch is internally powered by the uninterruptible power supply for use with non powered switch circ...

Страница 20: ...ation about the disposal of sealed lead acid batteries outside of the United States contact your local IBM service or ganization Replacing the Network Management Card Refer to the Network Management C...

Страница 21: ...ng of the CRU part numbers available at the time this document was published INDEX CRU PART DESCRIPTION 1 25R5591 Replacement Battery Module 2 73P5767 Serial Cable 3 25R5596 Serial to USB Adapter Cabl...

Страница 22: ...tible power supply is protecting the connected equip ment from occasional utility power irregularities UNINTERRUPTIBLE POWER SUPPLY IS NOT PROVIDING EXPECTED BACKUP TIME The uninterruptible power supp...

Страница 23: ...er to connected equipment The connected equipment exceeds the specified maximum load Disconnect nonessential equipment from the uninterruptible power supply to eliminate the overload condition Press t...

Страница 24: ...the diagnostic programs The troubleshooting information or the diagnos tic programs might tell you that you need additional or updated device drivers or other software IBM maintains pages on the World...

Страница 25: ...e in transit Never use Styrofoam beads for packaging Damage sustained in transit is not covered under war ranty Attention Always disconnect the battery before shipping The battery can remain in the un...

Страница 26: ...described in this publication at any time without notice Any references in this information to non IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of t...

Страница 27: ...uit boards cables electromagnetic compatibility gaskets and connectors which may contain lead and copper beryllium alloys that require special handling and disposal at end of life Before this unit is...

Страница 28: ...luding interference that may cause undesired operation Industry Canada Class A emission compliance statement This Class A digital apparatus complies with Canadian ICES 003 Avis de conformit la r gleme...

Страница 29: ...25 Taiwan electronic emission statement Chinese Class A warning statement Statement of Conformity to the Voluntary Control Council for Interference from Informa tion...