3.
Attention:
Some
electrical
circuits
could
be
damaged
if
the
external
signal
cables
are
present
at
the
SAN
Volume
Controller
while
the
grounding
check
is
being
done.
Ensure
that
no
external
cables
are
present
at
connectors
2
and
3
.
4.
Disconnect
and
remove
the
Ethernet
cable.
5.
Follow
your
local
procedures
and
check
the
grounding
of
the
SAN
Volume
Controller.
Any
test
equipment
must
be
connected
to
the
frame
of
the
SAN
Volume
Controller.
If
the
grounding
is
correct,
go
no
further
with
these
instructions.
If
the
grounding
is
not
correct,
unplug
the
power
cable
1
from
the
uninterruptible
power
supply
in
the
SAN
Volume
Controller.
6.
Check
for
continuity
between
the
frame
of
the
SAN
Volume
Controller
and
the
ground
pin
1
of
each
main
power
connector
as
shown
in
7.
If
the
uninterruptible
power
supply
has
no
continuity,
exchange
it
for
a
new
one.
Then
perform
a
complete
grounding
check
again.
If
the
uninterruptible
power
supply
has
continuity,
you
might
have
a
problem
with
the
power
cable
or
with
the
grounding
of
the
host
system.
8.
Check
the
power
cable
for
continuity.
If
the
power
cable
does
not
have
continuity,
exchange
it
for
a
new
one,
then
perform
step
through
step
again.
Inspecting
the
uninterruptible
power
supply
for
unsafe
conditions
Be
cautious
of
potential
safety
hazards
that
are
not
covered
in
the
safety
checks.
If
unsafe
conditions
are
present,
determine
how
serious
the
hazards
are
and
whether
you
should
continue
before
correcting
the
problem.
Prerequisites:
Consider
the
following
conditions
and
the
safety
hazards
they
present:
Electrical
hazards
(especially
primary
power)
Primary
voltage
on
the
frame
can
cause
serious
or
lethal
electrical
shock.
Explosive
hazards
A
bulging
capacitor
can
cause
serious
injury.
Mechanical
hazards
Loose
or
missing
items
(for
example,
nuts
and
screws)
can
cause
serious
injury.
1
Figure
2.
Ground
pin
xiv
Installation
Guide
Содержание TotalStorage
Страница 1: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 1 2 0 SC26 7541 02...
Страница 2: ......
Страница 3: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 1 2 0 SC26 7541 02...
Страница 22: ...xx Installation Guide...
Страница 36: ...14 Installation Guide...
Страница 58: ...36 Installation Guide...
Страница 74: ...52 Installation Guide...
Страница 80: ...58 Installation Guide...
Страница 84: ...62 Installation Guide...
Страница 89: ......
Страница 90: ...Part Number 64P8120 Printed in USA SC26 7541 02 1P P N 64P8120...
Страница 91: ...Spine information IBM TotalStorage SAN Volume Controller Installation Guide Version 1 2 0...