2.
Check
the
frame
for
damage
(loose,
broken,
or
sharp
edges).
3.
Check
the
power
cables
and
ensure
that:
a.
The
third-wire
ground
connector
is
in
good
condition.
Use
a
meter
to
check
that
the
third-wire
ground
continuity
is
0.1
ohm
or
less
between
the
external
ground
pin
and
the
frame
ground.
b.
The
insulation
is
not
worn
or
damaged.
4.
Check
for
any
obvious
nonstandard
changes.
Use
good
judgment
about
the
safety
of
any
such
changes.
5.
Check
inside
the
SAN
Volume
Controller
for
any
obvious
unsafe
conditions,
such
as
metal
particles,
water
or
other
fluids,
or
marks
of
overheating,
fire,
or
smoke
damage.
6.
Check
for
worn,
damaged,
or
pinched
cables.
7.
Ensure
that
the
voltage
specified
on
the
product-information
label
matches
the
specified
voltage
of
the
electrical
power
outlet.
If
necessary,
verify
the
voltage.
8.
Inspect
the
power
supply
assemblies,
and
check
that
the
fasteners
(screws
or
rivets)
in
the
cover
of
the
power-supply
unit
have
not
been
removed
or
disturbed.
9.
Before
connecting
the
SAN
Volume
Controller
to
the
SAN,
check
the
grounding.
Related
topics:
v
External
machine
checks
This
topic
describes
the
checks
that
you
should
perform
on
the
outside
of
the
SAN
Volume
Controller.
Steps:
Perform
the
following
external
machine
checks
before
you
install
the
SAN
Volume
Controller:
1.
Verify
that
all
external
covers
are
present
and
are
not
damaged.
2.
Ensure
that
all
latches
and
hinges
are
in
the
correct
operating
condition.
3.
If
the
SAN
Volume
Controller
is
not
installed
in
a
rack
cabinet,
check
for
loose
or
broken
feet.
4.
Check
the
power
cord
for
damage.
5.
Check
the
external
signal
cable
for
damage.
6.
Check
the
cover
for
sharp
edges,
damage,
or
alterations
that
expose
the
internal
parts
of
the
device.
7.
Correct
any
problems
that
you
find.
Related
topics:
v
Internal
machine
checks
This
topic
describes
the
checks
that
you
should
perform
on
the
inside
of
the
SAN
Volume
Controller.
Steps:
xii
Installation
Guide
Содержание TotalStorage
Страница 1: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 1 2 0 SC26 7541 02...
Страница 2: ......
Страница 3: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 1 2 0 SC26 7541 02...
Страница 22: ...xx Installation Guide...
Страница 36: ...14 Installation Guide...
Страница 58: ...36 Installation Guide...
Страница 74: ...52 Installation Guide...
Страница 80: ...58 Installation Guide...
Страница 84: ...62 Installation Guide...
Страница 89: ......
Страница 90: ...Part Number 64P8120 Printed in USA SC26 7541 02 1P P N 64P8120...
Страница 91: ...Spine information IBM TotalStorage SAN Volume Controller Installation Guide Version 1 2 0...