DS4100
specifications
Table
9
lists
the
physical
specifications
for
the
DS4100.
Table
9.
IBM
TotalStorage
DS4100
specifications
Size
v
Width
:
48.18
cm
(18.97
in.)
v
Height
:
13.23
cm
(5.21
in.)
v
Depth
:
59.74
cm
(23.52
in.)
Weight
v
Drive-ready
weight
(without
disk
drive
modules
installed):
–
Model
100:
26.64
kg
(58.9
lb)
–
Model
1S
x
:
23.44
kg
(51.9
lb)
v
Fully
configured
weight
(with
14
disk
drives
installed):
–
Model
100:
40.36
kg
(89
lb)
–
Model
1S
x
:
37.16
kg
(82
lb)
Environment
v
Air
temperature
–
Operating:
-
Altitude:
0
-
914
m
(3000
ft):
10°
-
35°
C
(50°
-
95°
F)
-
Altitude:
914
m
-
2133
m
(3000
-
7000
ft):
10°
-
32°
C
(50°
-
90°
F)
Important:
The
recommended
operating
environment
air
temperature
is
22°
C
(72°
F)
or
lower.
–
Storage:
-
Altitude:
0
-
914
m
(3000
ft):
1°
-
60°
C
(33°
-
140°
F)
-
Altitude:
914
m
-
2133
m
(3000
-
7000
ft):
1°
-
57°
C
(33°
-
135°
F)
v
Humidity
–
8%
-
80%
–
Noncondensing
Heat
dissipation
v
Fully
configured
storage
server
(14
1.5
Gbps
SATA
hard
disk
drives)
–
1235
BTU
per
hour
Acoustical
noise
emission
values
For
open
bay
(0
drives
installed)
and
typical
system
configurations
(eight
hard
disk
drives
installed):
v
Sound
power
(idling):
–
5.9
bel
(open
bay)
–
6.1
bel
(typical)
v
Sound
power
(operating):
–
5.9
bel
(open
bay)
–
6.2
bel
(typical)
v
Sound
pressure
(idling):
–
44
dBA
(open
bay)
–
46
dBA
(typical)
v
Sound
pressure
(operating):
–
44
dBA
(open
bay)
–
47
dBA
(typical)
These
levels
are
measured
in
controlled
acoustical
environments
according
to
ISO
7779
and
are
reported
in
accordance
with
ISO
9296.
The
declared
sound
power
levels
indicate
an
upper
limit,
below
which
a
large
portion
of
machines
operate.
Sound
pressure
levels
in
your
location
might
exceed
the
average
1-meter
values
stated
because
of
room
reflections
and
other
nearby
noise.
Notes:
1.
The
nonoperating
environment
must
not
exceed
the
operating
environment
limits
for
longer
than
60
days.
2.
The
storage
environment
must
not
exceed
the
operating
environment
limits
for
longer
than
1
year.
3.
Substantial
deviations
from
the
suggested
operating
range,
in
either
direction,
if
sustained
for
extended
periods
of
time,
will
expose
the
unit
to
greater
risk
of
failure
from
external
causes.
The
AC
power
sources
must
provide
the
correct
voltage,
current,
and
frequency
specified
on
the
storage
server.
The
storage
server
can
run
without
interruption
within
the
limits
shown
in
Table
10
on
page
15.
14
IBM
TotalStorage
DS4100
Storage
Server:
Installation,
User’s,
and
Maintenance
Guide
Содержание TotalStorage DS4100
Страница 1: ...IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide GC26 7712 00...
Страница 2: ......
Страница 3: ...IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide GC26 7712 00...
Страница 10: ...viii IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 18: ...xvi IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 32: ...xxx IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 76: ...44 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 96: ...64 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 109: ...Battery LED f10ug037 Figure 61 Battery LED Chapter 4 Operating the storage server 77...
Страница 110: ...78 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 150: ...118 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 152: ...120 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 156: ...124 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 172: ...140 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 179: ......
Страница 180: ...Part Number 25R0314 Printed in USA GC26 7712 00 1P P N 25R0314...