Attention:
The
DS4100
single-controller
storage
server
does
not
support
hot-swap
RAID
controllers
or
power
supplies.
You
will
lose
access
to
data
if
you
attempt
to
remove
or
replace
a
functioning
(non-failed)
RAID
controller
or
power
supply
in
a
DS4100
single-controller
storage
server
without
first
powering
down
the
storage
server.
Hot-swap
drive
bays
The
hot-swap
drive
bays
that
are
accessible
from
the
front
of
your
storage
server
are
shown
in
Figure
2.
The
DS4100
supports
up
to
14
DS4000
1.5
Gbps
SATA
hard
disk
drives.
These
drives
are
preinstalled
in
drive
trays.
The
unit
consisting
of
the
drive
and
the
drive
carrier
assembly
is
called
a
drive
CRU
.
The
SATA
drive
CRU
includes
the
drive
tray,
the
SATA
drive,
and
the
hard
disk
drive
(HDD)
interposer
card.
You
install
the
drive
CRUs
in
the
14
drive
bays
on
the
front
of
the
storage
server.
There
are
no
serviceable
parts
in
a
drive
CRU.
If
it
fails,
it
must
be
replaced
in
its
entirety
(drive,
interposer,
bezel,
and
tray).
Attention:
1.
Never
hot-swap
a
drive
CRU
when
its
associated
green
Activity
LED
is
flashing.
Hot-swap
a
drive
CRU
only
when
its
associated
amber
Fault
LED
lights
and
is
not
flashing
or
when
the
drive
is
inactive
and
its
associated
green
Activity
LED
lights
and
is
not
flashing.
2.
The
SATA
drive
and
its
HDD
card
are
digitally
signed
together
at
the
factory.
Do
not
swap
drives
and
interposers
between
drive
CRUs.
Do
not
replace
one
SATA
drive
with
another
SATA
drive.
These
actions
will
result
in
a
drive
CRU
that
cannot
be
recognized
by
the
storage
server
RAID
controller.
3.
After
you
remove
a
drive
CRU,
wait
at
least
70
seconds
before
replacing
or
reseating
the
drive
CRU
to
allow
the
drive
to
properly
spin
down.
Failure
to
do
so
may
cause
undesired
events.
Note:
If
the
hard
disk
drive
you
want
to
remove
is
not
in
a
failed
or
bypass
state,
always
use
the
DS4000
Storage
Manager
client
program
either
to
place
the
drive
in
a
failed
state
or
to
place
the
array
that
is
associated
with
the
drive
(or
drives)
in
an
offline
state
before
you
remove
the
drive
from
the
enclosure.
Front
controls
and
indicators
This
section
describes
the
primary
controls
on
the
front
of
the
storage
server.
The
locations
of
these
primary
controls
are
shown
in
Figure
3
on
page
9.
Hot-swap drive bays
f10ug052
Figure
2.
DS4100
hot-swap
drive
bays
8
IBM
TotalStorage
DS4100
Storage
Server:
Installation,
User’s,
and
Maintenance
Guide
Содержание TotalStorage DS4100
Страница 1: ...IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide GC26 7712 00...
Страница 2: ......
Страница 3: ...IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide GC26 7712 00...
Страница 10: ...viii IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 18: ...xvi IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 32: ...xxx IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 76: ...44 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 96: ...64 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 109: ...Battery LED f10ug037 Figure 61 Battery LED Chapter 4 Operating the storage server 77...
Страница 110: ...78 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 150: ...118 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 152: ...120 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 156: ...124 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 172: ...140 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 179: ......
Страница 180: ...Part Number 25R0314 Printed in USA GC26 7712 00 1P P N 25R0314...