Clustering
support
Clustering
is
a
means
of
sharing
array
groups
among
controllers
to
provide
redundancy
of
controllers
and
servers.
This
redundancy
is
important
if
a
hardware
component
fails.
If
a
hardware
component
failure
occurs
in
a
cluster,
another
server
takes
ownership
of
the
array
group.
Clustering
requires
software
specific
to
your
operating
system.
For
more
information
about
clustering,
go
to
the
following
Web
site:
www.pc.ibm.com/us/compat/nos/matrix.shtml
Inventory
checklist
After
you
unpack
the
DS4100
storage
server,
verify
that
you
have
the
following
items:
v
Hardware
–
Up
to
14
hard
disk
drives
(shipped
installed
in
the
DS4100)
Note:
The
DS4100
base
storage
server
is
shipped
with
no
SATA
hard
disk
drives
as
standard.
You
can
order
the
unit
with
up
to
14
250
GB
SATA
drive
CRUs
installed
at
the
factory.
The
DS4100
single-controller
storage
server
is
shipped
with
three
250
GB
SATA
drive
CRUs
as
standard.
You
can
order
the
unit
with
up
to
11
additional
SATA
drive
CRUs
installed
at
the
factory.
–
RAID
controllers
(shipped
installed
in
the
DS4100)
-
2
controllers
on
the
base
storage
server
-
1
controller
on
the
single-controller
storage
server
Note:
A
blank
controller
tray
is
installed
in
the
empty
controller
slot
in
the
DS4100
single-controller
storage
server
chassis.
For
proper
cooling
and
EMI
shielding,
do
not
remove
this
blank
controller
tray.
–
Two
fan
units
(shipped
installed
in
the
DS4100)
–
Power
supplies
(shipped
installed
in
the
DS4100)
-
2
power
supplies
on
the
base
storage
server
-
1
power
supply
on
the
single-controller
storage
server
Note:
A
blank
power
supply
tray
is
installed
in
the
empty
power
supply
slot
in
the
DS4100
single-controller
storage
server
chassis.
For
proper
cooling
and
EMI
shielding,
do
not
remove
this
blank
power
supply
tray.
–
Line
cord
jumpers
-
2
line
cord
jumpers
on
the
base
storage
server
-
1
line
cord
jumper
on
the
single-controller
storage
server
Line
cord
jumpers
are
power
cords
used
to
connect
the
DS4100
power
supply
units
to
the
IBM-certified
rack
power
distribution
units
(PDUs).
–
One
rack-mounting
hardware
kit,
including:
-
Two
rails
(right
and
left
assembly)
-
Eight
M6
black
hex-head
slotted
screws
-
Eight
M6
cage
nuts
-
Eight
M6
clip
nuts
–
Up
to
14
blank
drive
trays
(shipped
installed
in
the
DS4100)
Chapter
1.
Introduction
5
Содержание TotalStorage DS4100
Страница 1: ...IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide GC26 7712 00...
Страница 2: ......
Страница 3: ...IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide GC26 7712 00...
Страница 10: ...viii IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 18: ...xvi IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 32: ...xxx IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 76: ...44 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 96: ...64 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 109: ...Battery LED f10ug037 Figure 61 Battery LED Chapter 4 Operating the storage server 77...
Страница 110: ...78 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 150: ...118 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 152: ...120 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 156: ...124 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 172: ...140 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Страница 179: ......
Страница 180: ...Part Number 25R0314 Printed in USA GC26 7712 00 1P P N 25R0314...