Table 60. Base Clusters and Additional Storage Component IP addresses
The TSSC IP address range changes from frame to frame, and each new frame increments by a multiple of 10. For
example, the first stand-alone frame range would be 10, and the second frame range would be 20.
If this is a clustered set of servers, the entry for the first server (A) will most likely be 10. For the entry for the
second server (B), you will also enter 10 for the frame number. The code will make the adjustment automatically
based on the answer you provide during the RAS package installation process that asks you if you are setting up
the second node. If you reply "Yes", the code will set the IP range for node 2 at 5 octets higher than what is set for
node 1 (server A). For example, if server A is set for 172.31.1.10 then server B will be set for 172.31.1.15.
Note:
Depending upon the address ranges available on the TSSC, the IBM Service representative may have to use
ranges other than those shown here.
Component
Port
IP Addresses:
Stand-alone server -or-
Node A in a cluster
(the server located in the
lower part of the rack)
Examples:
For eth3,
172.31.1.x0
For RSA or IMM,
172.31.1.x1
IP Addresses:
Node B in a cluster
(the server located in the
upper part of the rack)
Examples:
For eth3,
172.31.1.x5
For RSA or IMM,
172.31.1.x6
Server
eth3
Server
RSA or IMM
152
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide
Содержание System Storage TS7650G 3958 DD4
Страница 2: ......
Страница 7: ...Russia Electromagnetic Interference EMI Class A Statement 189 Index 191 Contents v...
Страница 8: ...vi IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 10: ...viii IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 12: ...x IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 16: ...xiv IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 30: ...xxviii IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 38: ...xxxvi IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 44: ...6 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 46: ...8 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 54: ...16 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 89: ...Figure 20 Clustered TS7650G power cabling Chapter 4 Installing the TS7650G hardware 51...
Страница 120: ...82 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 148: ...110 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 150: ...112 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 156: ...118 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 172: ...134 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 192: ...154 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 198: ...160 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 210: ...172 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 220: ...182 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 228: ...190 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Страница 231: ......
Страница 232: ...Part Number 46X6052 Printed in USA or Mexico GC53 1154 09 1P P N 46X6052...