7.
To
select
the
IOP
that
will
support
your
intended
console,
do
one
of
the
following:
v
If
the
adapter
to
be
used
for
the
intended
console
is
under
the
same
IOP
as
the
previous
console’s
adapter,
the
console
IOP
is
already
correctly
tagged.
Go
to
step
8.
v
If
the
adapter
to
be
used
for
intended
console
is
under
a
different
IOP
than
the
currently
configured
console,
place
a
1
in
front
of
the
IOP
to
select
it
as
the
console
IOP.
8.
Verify
the
adapter
for
Electronic
Customer
Support
(ECS)
and
an
optional
alternate
console
(twinaxial
console
only).
Note:
The
selection
of
an
alternate
console
only
pertains
when
twinaxial
workstations
are
to
be
the
alternate
console
and
the
console
is
also
twinaxial
console.
The
alternate
console
must
be
under
a
different
IOP
than
the
IOP
tagged
for
use
by
Operations
Console.
Operations
Console
cannot
be
used
as
an
alternate
console.
v
To
verify
the
console
IOP
for
ECS,
perform
the
following
steps:
Note:
If
you
use
Operations
Console
as
your
console
type,
you
must
also
tag
the
same
IOP
used
for
the
console
as
the
IOP
for
ECS
even
if
you
do
not
use
ECS.
a.
Press
F12
until
you
arrive
at
the
Work
with
Partition
Configuration
window.
b.
Enter
a
9
in
front
of
the
partition
to
be
tagged
for
ECS.
c.
Look
at
the
symbols
on
the
same
line
as
the
tagged
console
IOP
(the
console
tag
is
the
<
symbol)
for
the
ECS
symbol
which
is
the
+
(the
plus
sign).
If
the
+
symbol
is
shown,
the
IOP
is
correctly
tagged
for
ECS.
Go
to
step
9.
d.
To
tag
the
console
IOP
for
ECS,
enter
a
1
in
front
of
the
IOP
to
be
tagged
for
ECS.
Note:
If
you
will
be
using
Operation
Console
as
the
intended
console
you
should
now
see
both
a
<
and
a
+
associated
with
the
console
IOP.
9.
Press
F3
to
exit
to
the
DST
main
menu.
10.
Select
Work
with
DST
environment
.
11.
Select
System
Devices
(skip
this
step
if
using
SST).
12.
Select
Select
Console
.
13.
Use
one
of
the
following
console
choices
to
select
the
new
console
type.
v
If
you
select
Operations
Console
(direct),
option
2,
continue
with
step
14.
v
If
you
select
Operations
Console
(LAN),
option
3,
do
the
following:
a.
The
Verify
Operations
Console
Adapters
window
appears.
This
is
the
resource
found
by
the
system
to
be
used
for
your
LAN
connection.
If
you
receive
the
message
No
valid
LAN
adapter
available
you
did
not
satisfy
the
hardware
requirements
for
Operations
Console.
If
so,
use
F3
to
exit
to
the
DST
main
menu,
then,
start
this
topic
again
at
step
1
above.
b.
Press
F11
to
configure
the
adapter.
c.
Enter
the
appropriate
network
data.
d.
Press
F7
to
store
the
data.
e.
Press
F14
to
activate
the
adapter
for
use
by
Operations
Console.
14.
Press
F3
until
you
return
to
the
DST
main
menu.
The
system
is
now
configured
for
use
by
your
intended
console
type.
If
you
do
not
plan
to
use
the
twinaxial
device
as
an
backup
console
do
not
remove
it
or
its
adapter
at
this
time.
You
may
need
it
to
debug
a
problem.
The
system
value
QAUTOCFG
must
be
set
to
ON
.
Use
one
of
the
following
methods
to
verify
or
set
this
system
value:
v
Use
the
WRKSYSVAL
QAUTOCFG
command.
Operations
Console
75
|
|
|
|
Содержание System i
Страница 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 2: ......
Страница 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 8: ...vi System i Connecting to System i Operations Console ...
Страница 120: ...112 System i Connecting to System i Operations Console ...
Страница 124: ...116 System i Connecting to System i Operations Console ...
Страница 125: ......
Страница 126: ... Printed in USA ...