c.
Look
at
the
symbols
on
the
same
line
as
the
tagged
console
IOP
(the
console
tag
is
the
<
symbol),
for
the
ECS
symbol
which
is
the
+
(the
plus
sign).
If
the
+
symbol
is
shown,
the
IOP
is
correctly
tagged
for
ECS.
Go
to
step
9.
d.
To
tag
the
console
IOP
for
ECS,
enter
a
1
in
front
of
the
IOP
to
be
tagged
for
ECS.
Note:
If
you
will
be
using
Operation
Console
as
the
intended
console
you
should
now
see
both
a
<
and
a
+
associated
with
the
console
IOP.
9.
Press
F3
to
return
to
the
DST
main
menu.
10.
Select
Work
with
DST
environment
(skip
this
step
if
using
SST).
11.
Select
System
Devices
(skip
this
step
if
using
SST).
12.
Select
Select
Console
.
13.
Select
Operations
Console
(LAN)
:
The
Verify
Operations
Console
Adapters
window
appears.
This
is
the
resource
found
by
the
system
to
be
used
for
your
LAN
connections.
Note:
If
this
resource
will
be
used
for
the
service
tools
server
(iSeries
Navigator
connections)
or
you
plan
to
use
the
local
console
on
a
network
(LAN)
as
a
backup
console
then
you
won’t
need
to
do
the
clear.
If
either
of
these
choices
is
true,
continue
with
step
17.
14.
Press
F6
to
perform
a
clear.
15.
Press
F7
to
store
the
new
values.
16.
If
you
are
not
currently
using
this
resource
for
the
console
connection,
press
F13
to
deactivate
the
adapter.
You
will
be
required
to
use
another
console
type
or
resource
on
the
next
IPL.
Note:
If
you
are
doing
this
work
from
a
local
console
on
a
network
connection,
this
deactivation
will
cause
your
console
connection
to
close
and
you
may
not
be
able
to
restart
it
without
an
IPL.
17.
Press
F12
twice
to
exit
this
window.
You
should
return
to
the
Work
with
System
Devices
window.
If
you’re
using
SST,
this
returns
you
to
Work
with
Service
Tools
User
IDs
and
Devices.
18.
Select
Select
Console
.
19.
Select
Operations
console
(direct)
.
Important:
You
must
change
the
console
type
to
something
other
than
Operations
Console
(LAN)
or
the
adapter
will
get
reallocated
on
the
next
IPL.
20.
Press
F3
until
you
return
to
the
DST
main
menu.
The
system
is
now
configured
for
use
by
your
intended
console
type.
If
you
do
not
plan
to
use
the
local
console
on
a
network
(LAN)
configuration
as
a
backup
console,
do
not
remove
or
move
the
LAN
adapter
at
this
time.
If
you
encounter
a
problem
with
your
new
console
choice,
you
might
need
this
resource
to
debug
the
problem.
When
you
get
your
new
console
choice
working,
you
can
remove
it
from
the
system
or
move
it
to
another
location.
The
system
value
QAUTOCFG
must
be
set
to
on.
Use
one
of
the
following
methods
to
verify
or
set
this
system
value:
v
Use
the
WRKSYSVAL
QAUTOCFG
command.
v
During
a
manual
IPL,
in
the
IPL
Options
window,
select
Y
for
Set
major
system
options.
Then,
for
Enable
automatic
configuration
,
select
Y
.
Related
tasks
After
changing
from
a
local
console
on
a
network
to
a
local
console
directly
attached,
you
must
configure
the
PC
to
use
the
new
console
type.
Related
information
72
System
i:
Connecting
to
System
i
Operations
Console
|
|
|
|
|
|
|
Содержание System i
Страница 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 2: ......
Страница 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 8: ...vi System i Connecting to System i Operations Console ...
Страница 120: ...112 System i Connecting to System i Operations Console ...
Страница 124: ...116 System i Connecting to System i Operations Console ...
Страница 125: ......
Страница 126: ... Printed in USA ...