![IBM System i Скачать руководство пользователя страница 79](http://html.mh-extra.com/html/ibm/system-i/system-i_manual_607100079.webp)
The
system
value
QAUTOCFG
must
be
set
to
on.
Use
one
of
the
following
methods
to
verify
or
set
this
system
value:
v
Use
the
WRKSYSVAL
QAUTOCFG
command.
v
During
a
manual
IPL,
in
the
IPL
Options
window,
select
Y
for
Set
major
system
options.
Then,
for
Enable
automatic
configuration
,
select
Y
.
Continue
with
Configure
the
PC
to
use
the
new
console
type.
Related
tasks
After
changing
from
a
local
console
on
a
network
to
a
local
console
directly
attached,
you
must
configure
the
PC
to
use
the
new
console
type.
Related
information
Changing
the
console
from
local
console
on
a
network
(LAN)
to
a
local
console
directly
attached
for
a
logical
partition:
To
migrate
Operations
Console
with
a
local
console
on
a
network
(LAN)
to
a
local
console
directly
attached,
follow
these
steps
on
the
system
using
the
existing
console.
Note:
If
you
need
to
add
or
move
adapters
to
satisfy
the
hardware
requirements
for
Operations
Console,
do
this
work
prior
to
starting
these
migration
steps.
1.
Access
Dedicated
Service
Tools
(DST)
or
System
Service
Tools
(SST).
2.
Select
Work
with
System
Partitions
.
3.
Select
Work
with
partition
configuration
.
4.
Choose
Select
Console
Resource
on
the
logical
partition.
5.
Press
F9
to
Change
capability
filter
.
6.
Select
Any
Console
(option
4).
7.
To
select
the
IOP
that
will
support
your
intended
console,
do
one
of
the
following:
v
If
the
adapter
to
be
used
for
the
intended
console
is
under
the
same
IOP
as
the
previous
console’s
adapter,
the
console
IOP
is
already
correctly
tagged.
Go
to
step
8.
v
If
the
adapter
to
be
used
for
the
intended
console
is
under
a
different
IOP
than
the
currently
configured
console,
place
a
1
in
front
of
the
IOP
to
select
it
as
the
console
IOP.
8.
Verify
an
adapter
for
Electronic
Customer
Support
(ECS)
and
an
optional
alternate
console.
v
To
verify
the
tagging
for
an
alternate
console,
find
the
IOP
with
the
twinaxial
adapter
that
will
be
used
for
the
alternate
console.
It
is
properly
tagged
if
you
see
a
>
(greater
than)
symbol
on
the
same
line.
If
the
>
is
not
on
this
line,
enter
an
option
2
in
front
of
the
IOP
being
selected
as
the
alternate
console.
Note:
The
selection
of
an
alternate
console
only
pertains
when
twinaxial
workstations
are
to
be
the
alternate
console
and
the
console
type
is
also
twinaxial
console.
The
alternate
console
must
be
under
a
different
IOP
than
the
IOP
tagged
for
use
by
Operations
Console.
Operations
Console
cannot
be
used
as
an
alternate
console.
v
To
verify
the
console
IOP
for
ECS,
perform
the
following
steps:
Note:
If
you
use
Operations
Console
as
your
console
type,
you
must
also
tag
the
same
IOP
used
for
the
console
as
the
IOP
for
ECS
even
if
you
do
not
use
ECS.
a.
Press
F12
until
you
arrive
at
the
Work
with
Partition
Configuration
window.
b.
Enter
a
9
in
front
of
the
partition
to
be
tagged
for
ECS.
Operations
Console
71
|
|
|
|
|
|
|
Содержание System i
Страница 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 2: ......
Страница 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 8: ...vi System i Connecting to System i Operations Console ...
Страница 120: ...112 System i Connecting to System i Operations Console ...
Страница 124: ...116 System i Connecting to System i Operations Console ...
Страница 125: ......
Страница 126: ... Printed in USA ...