3.
A
new
Connect
To
window
will
appear.
Click
the
little
arrow
at
the
end
of
line
for
Connect
using:
4.
Select
the
communications
port
being
used
for
the
console.
It
might
also
be
listed
as
direct
to
COMn
(where
n
is
1
to
4).
Click
OK
.
5.
A
COMn
Properties
window
will
appear.
Change
the
speed
to
9600
.
Click
OK
.
Note:
Failure
to
set
the
speed
to
9600
will
result
in
all
unintelligible
text
and
you
will
not
see
the
desired
results.
6.
The
HyperTerminal
window
will
open.
In
the
lower-left
corner
the
status
should
report
as
Connected
and
the
time
will
be
incrementing.
7.
In
the
data
window
you
may
get:
v
Nothing
v
Unintelligible
v
+++ATH0
8.
Do
a
Disconnect
.
9.
Select
File
→
Properties
.
10.
You
should
be
in
the
Properties
for
the
connection
you
just
created.
Select
the
Settings
tab.
11.
Click
ASCII
Setup
.
12.
Change
the
following
settings
so
there
is
a
check
mark
in
the
check
box:
v
Send
line
ends
with
line
feeds
v
Echo
typed
characters
locally
v
Append
line
feeds
to
incoming
line
ends
v
Wrap
lines
that
exceed
terminal
width
13.
Click
OK
.
Click
OK
.
14.
Do
a
Connect
.
15.
At
the
system’s
control
panel,
enter
function
65
(you
need
to
take
the
system
to
a
known
state).
Note:
You
may
need
to
enter
function
25
and
26
in
order
to
have
access
to
the
upper
functions.
16.
The
system’s
control
panel
might
display
D1008065
after
a
while.
Also,
in
the
HyperTerminal
window,
you
might
receive
some
data.
17.
At
the
system’s
control
panel,
enter
function
66
.
You
might
see
D1008066
.
Also,
in
the
HyperTerminal
window,
you
might
receive
some
data.
18.
Using
uppercase,
type
NEGOTIATE
1
in
the
HyperTerminal
window.
Press
Enter.
The
HyperTerminal
data
window
displays
115200
.
Note:
If
nothing
is
returned,
repeat
NEGOTIATE
1
.
If
a
speed
value
is
returned,
you
had
data
exchanged
in
both
directions
and
have
full
connectivity.
If
Operations
Console
will
not
connect,
more
than
likely
you
have
a
setup
problem
on
the
client
side.
If
a
speed
value
is
not
returned,
you
might
try
turning
off
the
PC,
turn
it
back
on,
and
repeat
the
test.
Alternatively,
you
can
try
connecting
to
the
console
again.
In
rare
cases,
the
system
might
need
an
IPL.
For
the
best
results,
it
is
suggested
that
you
follow
these
steps:
a.
Turn
off
the
system.
b.
Turn
off
the
PC.
c.
Turn
on
the
PC.
d.
Start
a
connection
for
the
console.
e.
Turn
on
the
system.
If
the
above
process
fails
to
solve
your
connection
problem,
you
need
to
contact
your
service
provider
for
further
assistance.
Related
tasks
Operations
Console
103
Содержание System i
Страница 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 2: ......
Страница 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 8: ...vi System i Connecting to System i Operations Console ...
Страница 120: ...112 System i Connecting to System i Operations Console ...
Страница 124: ...116 System i Connecting to System i Operations Console ...
Страница 125: ......
Страница 126: ... Printed in USA ...