Related
reference
When
setting
up
your
local
console,
you
might
encounter
problems
connecting.
Failure
to
connect
is
defined
as
problems
resulting
in
the
status
not
going
to
Connected
and
the
emulator
did
not
start.
PC5250
window
does
not
display
user
data
This
can
be
caused
by
a
non-buffered
UART
for
the
serial
connection
in
the
PC.
See
the
Performance
degradation
on
local
console
topic.
This
problem
only
affects
a
direct
attach
local
console.
Related
reference
The
most
likely
reason
for
performance
degradation
is
that
the
communication
port
is
not
running
a
buffered
UART
(Universal
Asynchronous
Receive/Transmit
serial
port
chip).
Troubleshooting
system
reference
code
data
If
you
receive
any
of
these
system
reference
codes
(SRCs),
you
might
have
some
problems
in
your
Operations
Console
configuration.
Refer
to
the
sections
below
to
find
information
about
specific
system
reference
codes
and
troubleshooting
options.
System
reference
code
A6nn500x
These
are
the
system
reference
codes
(SRCs)
used
to
access
console
types
and
console
tasks.
These
SRCs
are
associated
with
the
operation
of
the
control
panel
method
to
change
the
console
type
or
accomplish
a
console
task
when
the
console
or
other
workstation
is
not
available.
Remember:
nn
can
be
any
alphanumeric
designation.
v
A6nn
500A
-
You
are
displaying
the
current
console
type
setting.
v
A6nn
500B
-
You
did
a
second
65+21
so
you
are
in
edit
mode.
v
A6nn
500C
-
You
executed
a
second
21
to
cause
an
action,
such
as
setting
the
console
to
another
value.
v
A6nn
500D
-
You
waited
too
long
after
entering
edit
mode
to
cause
an
action
so
you
will
have
to
reenter
edit
mode
again
if
you
intended
to
make
the
change.
A
21
at
this
time
will
force
the
console
to
DST,
not
cause
an
action.
Related
reference
Console
service
functions
(65+21)
are
the
emergency
console
recovery
functions.
System
reference
code
A6005001,
A6005004,
and
A6005007
These
system
reference
codes
(SRCs)
might
be
displayed
for
twinaxial
consoles.
A6005001
A
console
resource
(controller)
was
not
found
during
a
manual
IPL.
A6005004
A
console
device
was
not
found
during
a
manual
IPL.
A
twinaxial
controller
was
found
but
may
not
be
used.
This
is
only
indicating
the
presence
of
a
controller.
It
is
not
indicating
the
controller
may
be
defective.
Operations
Console
105
|
|
|
|
|
Содержание System i
Страница 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 2: ......
Страница 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 8: ...vi System i Connecting to System i Operations Console ...
Страница 120: ...112 System i Connecting to System i Operations Console ...
Страница 124: ...116 System i Connecting to System i Operations Console ...
Страница 125: ......
Страница 126: ... Printed in USA ...