3-6
ServeRAID M5025 SAS/SATA Controller Characteristics
3.3.4
Power Supply Requirements for the ServeRAID M5025
SAS/SATA Controller
All power is supplied to the ServeRAID M5025 SAS/SATA controller
through the PCI Express 3.3V rails and the 12V rail. Onboard switching
regulator circuitry operating from the 3.3V rails and the 12V rail provide
the necessary voltages. The following states determine the typical
current consumption of the controller:
State 1: During a hard reset
State 2: During a disk stress test
State 3: While sitting idle at the DOS prompt
The supply voltages are 12V ± 8 percent (from PCI edge connector only)
and
3.3V ± - 9 percent (from PCI edge connector only).
lists
the power supply for the controller for each of the three states at the
different voltages.
Table 3.5
Fault Tolerance Features
Specification
ServeRAID M5025 SAS/SATA Controller
Support for SMART
1
1.
The Self Monitoring Analysis and Reporting Technology (SMART) detects
up to 70 percent of all predictable drive failures. In addition, SMART
monitors the internal performance of all motors, heads, and drive
electronics.
Yes
Optional Battery Backup for
Cache Memory
iBBU battery backup. <3.7V/1400mAH battery
pack; up to 72 hours of data retention for
512 Mbytes
Drive Failure Detection
Automatic
Drive Rebuild Using Hot Spares Automatic
Parity Generation and Checking Yes
Содержание ServeRAID M5025
Страница 1: ...ServeRAID M5025 SAS SATA Controller USER S GUIDE S e p t e m b e r 2 0 1 1...
Страница 12: ...xii Contents...
Страница 14: ...xiv Contents...
Страница 16: ...xvi Contents...
Страница 48: ...3 8 ServeRAID M5025 SAS SATA Controller Characteristics...
Страница 78: ...A 4 Notices...
Страница 84: ...B 6 Glossary of Terms and Abbreviations...
Страница 85: ......
Страница 86: ...Part number 60Y1428...