326
RackSwitch G8000: Application Guide
altSwVrrpNewBackup
Indicates that the sending agent has
transitioned to “Backup” state.
altSwVrrpAuthFailure
Signifies that a packet has been received from
a router whose authentication key or
authentication type conflicts with this router's
authentication key or authentication type.
Implementation of this trap is optional.
altSwLoginFailure
Signifies that someone failed to enter a valid
username/password combination.
altSwTempExceedThreshold
Signifies that the switch temperature has
exceeded maximum safety limits.
altSwTempReturnThreshold
Signifies that the switch temperature has
returned to under maximum safety limits.
altSwStgNewRoot
Signifies that the bridge has become the new
root of the STG.
altSwStgTopologyChanged
Signifies that there was a STG topology
change.
altSwStgBlockingState
An
altSwStgBlockingState
trap is sent
when port state is changed in blocking state.
altSwCistNewRoot
Signifies that the bridge has become the new
root of the CIST.
altSwCistTopologyChanged
Signifies that there was a CIST topology
change.
altSwHotlinksMasterUp
Signifies that the Master interface is active.
altSwHotlinksMasterDn
Signifies that the Master interface is not active.
altSwHotlinksBackupUp
Signifies that the Backup interface is active.
altSwHotlinksBackupDn
Signifies that the Backup interface is not
active.
altSwHotlinksNone
Signifies that there are no active interfaces.
Table 25.
IBM N/OS
-Supported Enterprise SNMP Traps (continued)
Trap Name
Description
Содержание RackSwitch G8000
Страница 1: ...RackSwitch G8000 Application Guide...
Страница 2: ......
Страница 3: ...RackSwitch G8000 Application Guide...
Страница 16: ...16 RackSwitch G8000 Application Guide...
Страница 22: ...20 RackSwitch G8000 Application Guide...
Страница 23: ...Copyright IBM Corp 2011 21 Part 1 Getting Started...
Страница 24: ...22 RackSwitch G8000 Application Guide...
Страница 54: ...52 RackSwitch G8000 Application Guide...
Страница 55: ...Copyright IBM Corp 2011 53 Part 2 Securing the Switch...
Страница 56: ...54 RackSwitch G8000 Application Guide...
Страница 92: ...90 RackSwitch G8000 Application Guide...
Страница 94: ...92 RackSwitch G8000 Application Guide...
Страница 144: ...142 RackSwitch G8000 Application Guide...
Страница 145: ...Copyright IBM Corp 2011 143 Part 4 Advanced Switch ing Features...
Страница 146: ...144 RackSwitch G8000 Application Guide...
Страница 148: ...146 RackSwitch G8000 Application Guide...
Страница 182: ...180 RackSwitch G8000 Application Guide...
Страница 184: ...182 RackSwitch G8000 Application Guide...
Страница 212: ...210 RackSwitch G8000 Application Guide...
Страница 258: ...256 RackSwitch G8000 Application Guide...
Страница 286: ...284 RackSwitch G8000 Application Guide...
Страница 294: ...292 RackSwitch G8000 Application Guide...
Страница 298: ...296 RackSwitch G8000 Application Guide...
Страница 310: ...308 RackSwitch G8000 Application Guide...
Страница 311: ...Copyright IBM Corp 2011 309 Part 7 Network Management...
Страница 312: ...310 RackSwitch G8000 Application Guide...
Страница 320: ...318 RackSwitch G8000 Application Guide...
Страница 332: ...330 RackSwitch G8000 Application Guide...
Страница 334: ...332 RackSwitch G8000 Application Guide...
Страница 345: ...Copyright IBM Corp 2011 343 Part 9 Appendices...
Страница 346: ...344 RackSwitch G8000 Application Guide...
Страница 357: ...Copyright IBM Corp 2011 Appendix C Notices 355 Taiwan Class A compliance statement...
Страница 358: ...356 RackSwitch G8000 Application Guide...