6
603 Hardware Specifications, REV 2
Preliminary—Subject to Change without Notice
1.3.2 AC Electrical Characteristics
This section provides the clock and AC electrical characteristics for the 603.
1.3.2.1 Clock AC Specifications
Table 5 provides the clock AC timing specifications as defined in Figure 1. These specifications are for 25,
33.33, 40, 50, and 66.67 MHz bus clock (SYSCLK) frequencies.
Nap Mode
1
1:1
Typical
160
mW
2:1
Typical
140
160
mW
Sleep Mode
1
1:1
Typical
125
mW
2:1
Typical
110
130
mW
Sleep Mode—PLL Disabled
1
1:1
Typical
70
mW
2:1
Typical
30
40
mW
Sleep Mode—PLL and SYSCLK Disabled
1
1:1
Typical
2.0
mW
2:1
Typical
2.0
2.0
mW
Note
: 1. The values provided for this mode do not include pad driver power (OVDD) or analog supply power
(AVDD). Worst-case AVDD = 15 mW.
Table 5. Clock AC Timing Specifications
Vdd = 3.3
±
5% V dc, GND = 0 V dc
,
0
≤
T
J
≤
105
°
C
Num
Characteristic
25 MHz
33.33 MHz
40 MHz
50 MHz
66.67
Unit
Notes
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Frequency of
operation
16.67
25.0
25.0
33.33
33.33
40.0
40.0
50.0
50.0
66.67
MHz
1
SYSCLK cycle
time
40.0
60.0
30.0
40.0
25.0
30.0
20.0
25.0
15.0
20.0
ns
2,3
SYSCLK rise
and fall time
—
2.0
—
2.0
—
2.0
—
2.0
—
2.0
ns
1
4
SYSCLK duty
cycle
measured at
1.4 V
40.0
60.0
40.0
60.0
40.0
60.0
40.0
60.0
40.0
60.0
%
3
Table 4. Power Dissipation (Continued)
Vdd = 3.3
±
5% V dc, GND = 0 V dc, 0
≤
T
j
≤
105
°
C
CPU Clock:
SYSCLK
Bus Frequency (SYSCLK)
Unit
25 MHz
33 MHz
40 MHz
50 MHz
66 MHz