Chapter
1
Troubleshooting Display Messages
48
012 STRUCTURED FLD ERROR
Application software has violated
structured data field parameters.
Not a printer problem. Have the system administrator correct
applications data or configuration.
013 ACTIVATE LOST
The printer detects a twinax
protocol communication error and
reports the error.
1.
Power off and unplug the printer. Check the twinax host data
cable and twinax I/O cable connection at the CT board. Reseat
the twinax host data cable connection and the twinax I/O cable
connection at the CT board.
2.
Disconnect the twinax auto-termination cable from the printer.
Test the cable for the resistances shown on page 287. If
resistances are not correct, replace the twinax auto-termination
cable.
3.
Plug in the printer and power it on. Send a print job to the printer.
If the message appears, replace the twinax cable.
4.
Send a print job to the printer. If the message appears, go to
Communications Failures
, page 211.
014 INVALID ACTIVATE
The printer detects a twinax
protocol communications error
and reports the error.
1.
Power off and unplug the printer. Check the twinax host data
cable and twinax I/O cable connection at the CT board. Reseat
the twinax host data cable connection and the twinax I/O cable
connection at the CT board.
2.
Disconnect the twinax auto-termination cable from the printer or
from the last device on this twinax port. Test the cable for the
resistances shown on page 268. If the resistances are not correct,
replace the twinax auto-termination cable.
3.
Plug in the printer and power it on. Send a print job to the printer.
If the message appears, replace the twinax cable.
4.
Send a print job to the printer. If the message appears, go to
Communications Failures
, page 211.
Table 3. Message List
Operator Panel Message
Explanation
Corrective Action
Содержание Infoprint 6500-v05
Страница 282: ...282 Cable Routing Cabinet Model...
Страница 283: ...283 Cable Routing Pedestal Model...
Страница 285: ...285 Cable Assembly Centronics Dataproducts Adapter 14H5522...
Страница 286: ...286 Cable Assembly 5V Remote Power 14H5589 To Controller Board...
Страница 289: ...289 Cable Assembly PS I O 2000 75P1614 To Power Supply To Controller Board NOTE This cable is used only on the 6500 v20...
Страница 290: ...290 Cable Assembly AC In Power Supply To Power Supply J1 To Circuit Breaker Part of AC Kit 14H5289...
Страница 291: ...291 Cable Assembly AC Power Input To Circuit Breaker Input Power Connector Part of AC Kit 14H5289...
Страница 292: ...292 Cable Assembly Card Cage Fan PIN 1 PIN 1 14H5285...
Страница 294: ...294 Cable Assembly Exhaust Fan PIN 1 PIN 1 14H5286...
Страница 298: ...298 Cable Assembly MPU PIN 1 PIN 3 PIN 2 PIN 1 14H5329...
Страница 300: ...300 Cable Assembly Ribbon Motor Extension 63H7464...
Страница 301: ...301 Cable Assembly Shuttle Motor Drive 14H5330 To Shuttle To Controller Board...
Страница 302: ...302 Frame Cable Power Stacker 10R3912...
Страница 303: ...303 Logic Cable Power Stacker 10R4590...
Страница 304: ...304 Power Cable Power Stacker 57P1376 P1101 P1101...
Страница 305: ...305 Vertical Rail Cable Power Stacker 10R3913...
Страница 306: ...306 Elevator I O Cable Power Stacker 10R4053...
Страница 307: ...307 Fan Assembly Hammer Bank P107 HBF P107 HBF 14H5159...
Страница 308: ...308 Magnetic Pickup MPU Assembly 57G1476 P03...
Страница 309: ...309 Switch Assembly Paper Detector Standard 14H5281 Black Back Forms Kit 02N7169...
Страница 310: ...310 Switch Assembly Platen Interlock P107 PLO 14H5280...
Страница 530: ...530 WR Write w With w o Without XMT Transmit...
Страница 531: ...531...
Страница 544: ...G544 5978 00 07G544597800 Copyright IBM Corp 2005...