Table
3-1 (Page 29 of 40). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
40111101
Power good signal low on either
processor card 0 or processor card
1. (If the system is running, refer to
the AIX error log to find out which
processor card is failing. If the
system is not running, refer to the
service processor error log.)
For Model H50:
1. Check cable between PDB and CPU
card for proper seatin.
2. Replace failing processor card.
3. Replace cable between PDB and CPU
card.
4. Replace PDB.
For Model H70:
Replace failing processor card.
40111102
Wrong processor cards plugged into
the system
1. Remove cards.
2. Verify part numbers.
3. Install valid card.
40200001
An unknown cooling problem
detected
Cooling problem; check system fans.
40200021
A CPU temperature warning
detected
Over temperature on CPU card.
40200023
A critical CPU temperature condition
detected
Critical temperature on CPU card.
40200031
An I/O board temperature warning
detected
Over temperature on I/O board.
40200033
A critical I/O board temperature con-
dition detected
Critical temperature on I/O board.
40200041
A memory temperature warning
detected
Over temperature on the memory card.
40200043
A critical memory temperature con-
dition detected
Critical temperature on the memory card.
40200051
An inlet temperature warning
detected
Over temperature on the air flow inlet.
40200053
An inlet memory temperature condi-
tion detected
Critical temperature on the air flow inlet.
40210011
A slow fan detected
Check:
1. Room operating temperature.
2. System fans.
40210014
1. A stopped fan detected.
2. Fan connector unplugged.
3. Fan sensor defective.
4. Loss of a redundant fan and a
subsequent locked fan. (If the
system is running, refer to the
AIX error log to find out which
fan is failing. If the system is
not running, refer to the service
processor error log.)
1. Check connector.
2. Failing fan.
3. FMC card.
3-30
RS/6000 Enterprise Server Model H Series Installation and Service Guide
Содержание H Series
Страница 1: ...RS 6000 Enterprise Server Model H Series IBM Installation and Service Guide SA38 0547 01...
Страница 14: ...xiv RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 34: ...1 18 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 108: ...2 74 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 181: ...AIX and Physical Location Code Reference Table Model H50 Chapter 3 Error Code to FRU Index 3 73...
Страница 182: ...3 74 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 254: ...6 40 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 285: ...Chapter 7 Removal and Replacement Procedures 7 31...
Страница 305: ...Replacement To replace do the removal steps in the reverse order Chapter 7 Removal and Replacement Procedures 7 51...
Страница 322: ...7 68 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 323: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 324: ...3 2 1 4 5 12 6 7 13 8 9 10 11 8 2 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 328: ...42 41 36 33 34 35 37 38 39 40 8 6 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 336: ...8 14 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 348: ...A 12 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 422: ...E 28 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 426: ...F 4 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 433: ...Index X 7...
Страница 434: ...X 8 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 437: ......