4. Remove the fixed power supply (see the following illustration).
2
1
5. Disconnect all power-supply cables from the system board (J4, J10), SCSI
backplane, and other backplanes or devices.
6. From the rear of the server, remove the two screws at each side of the fixed
power supply.
7. Gently pull the power supply from the server, making sure the cables do not
snag on the chassis or system board.
Note:
You might need to insert the blade of a screwdriver behind one corner of
the power supply to begin moving it.
8. To install a non-hot-swap power supply option, reverse the previous steps.
Front fan housing
Complete the following steps to remove the blower housing.
Note:
v
Read “Installation guidelines” on page 41.
v
Read the safety notices at “Safety information” on page 163.
v
Read “Handling electrostatic discharge-sensitive devices” on page 166.
1. Turn off the server.
2. Disconnect all external cables and power cords from the back of the server.
3. Remove the front bezel (see “Removing the bezel” on page 52).
4. Remove the server cover (see “Removing the left-side cover” on page 51).
5. Remove the two front fans (see “Replacing a hot-swap fan” on page 91).
6. Disconnect and remove adapter cards and spacers (see “Working with
adapters” on page 56).
7. Remove the two central fans (see “Replacing a hot-swap fan” on page 91).
8. Remove the plastic baffle.
9. Remove the DASD backplane (see “DASD backplane” on page 117).
Chapter 5. Service replaceable units
119
Содержание eServer xSeries 235 Type 8671
Страница 1: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver ...
Страница 2: ......
Страница 3: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver ...
Страница 34: ...24 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 50: ...40 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 134: ...124 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 164: ...154 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 170: ...160 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 183: ...Appendix B Related service information 173 ...
Страница 184: ...174 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 185: ...Appendix B Related service information 175 ...
Страница 186: ...176 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 187: ...Appendix B Related service information 177 ...
Страница 188: ...178 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 189: ...Appendix B Related service information 179 ...
Страница 190: ...180 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 200: ...190 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 201: ...Appendix B Related service information 191 ...
Страница 202: ...192 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 206: ...196 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 211: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix C Notices 201 ...
Страница 212: ...202 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 213: ......
Страница 214: ... Part Number 59P6524 1P P N 59P6524 ...