10
xSeries 380: Installation Guide
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact a
service technician.
The power-supply status indicators provide the following information:
Power on
Predictive
failure
Failure
Power-supply status
Off
Off
Off
No power to any power supplies
Off
Off
On
Power-supply failure
Blinking
Off
Off
AC power present/standby output on
On
Off
Off
DC outputs on and working
On
Off
Blinking
Current limit
On
Blinking
Off
Predictive failure