6
xSeries 380: Installation Guide
Working with hot-swap hard disk drives
Your server supports two 1-inch (26 mm) slim, 3.5-inch hot-swap SCSI hard disk
drives in the hard disk drive bays.
Each hot-swap hard disk drive has three indicator lights: the power-on light, activity
light, and status light. The hard disk drive lights are illustrated and described in
“Controls and indicators” on page 15. If the amber hard disk drive status light is lit
continuously, that individual drive is faulty and requires replacement. You can replace
a hot-swap drive without turning off the server.
Attention: When you handle static-sensitive devices, take precautions to avoid
damage from static electricity. For details on handling these devices, see “Handling
static-sensitive devices” on page 4.
Note: To maintain proper system cooling, do not operate the server for more than 10
minutes without either a drive or a filler panel installed in each bay.
Complete the following steps to install a drive in a hot-swap bay:
1.
Review the information in “Before you begin” on page 3.
Notes:
a.
The illustrations in this document might differ slightly from your hardware.
b.
You do not have to turn off the server to install hot-swap hard disk drives.
2.
Align the drive assembly with the guide rails in the bay, and slide the drive into the
bay.
3.
Check the hard disk drive indicator lights to verify that the drive is functioning
properly. See “Controls and indicators” on page 15 for more information.
Attention: Do not press on the perforated metal bracket of the tray when you
push the assembly into the bay.
Содержание eServer 380 xSeries
Страница 3: ...IBM xSeries 380 Installation Guide SC06 P464 70...
Страница 6: ...iv xSeries 380 Installation Guide...
Страница 14: ...xii xSeries 380 Installation Guide...
Страница 32: ...18 xSeries 380 Installation Guide...
Страница 53: ......
Страница 54: ...IBM Part Number 06P4647 Printed in the United States of America 6P4647...