6.1.2 SCSI Cable
The drives comply with ANSI X3T10/1071D.
The maximum cumulative signal path length between terminators shall be 3.0 meters when using up to 4
maximum capacitance (25pF) devices.
The maximum cumulative signal path length between terminators shall be 1.5 meters when using from 5 to 8
maximum capacitance devices.
Implementation that limits the transfer rate to a maximum of 5 mega transfers per second may extend the
cumulative cable length to 6m as described in ANSI X3T10/855D.
6.1.3 SCSI Bus Terminator
The drives comply with ANSI X3T10/1071D.
Active terminator as specified in ANSI X3T10/1071D should be used.
Terminators employing a 220 ohm resistor to 5 Volts and 330 ohm resistor to ground on each signal shall
not be used. (Passive terminators should not be used for FAST-20.)
Note : The drive may not spin up while SCSI Bus is disconnected and internal terminator is disabled.
Internal terminator enabled by jumper plug is equipped in the drive except 80-pin (SCA-2) model.
The 80-pin (SCA-2) model does not have internal terminator.
6.1.4 Hot Plug / Unplug
Power supply and SCSI bus hot plug and unplug is allowed. There is no special sequence required for con-
necting 5 or 12 volts. During a hot plug-in event the drive being plugged will draw a large amount of current
at the instant of plug-in. This current spike is due to charging the bypass capacitors on the drive. This
current pulse may cause the power supply to go out of regulation. If this supply is shared by other drives
then a low voltage power on reset may be initiated on those drives. Therefore the recommendation for hot
plugging is to have one supply for each drive. Never daisy chain the power leads if hot plugging is planned.
Hot plugging should be minimized to prevent wear on the power connector.
Hot plugging of the SCSI bus may cause glitches on the bus. To minimize the chance of glitching, it is
recommended to plug in the SCSI bus before the power is applied.
During hot plugging, the supplies must not go over the upper voltage limit. In addition, proper ESD pro-
tection must be applied during the plugging event to insure that the SCSI bus ground is at the same poten-
tial as the drive ground.
If operating shock limit can be exceeded at hot un-plugging, spindle motor should be stopped using SCSI
Stop Unit command prior to the hot un-plugging.
24
O E M Spec. of DCAS-34330/32160
Содержание DCAS-32160 - Ultrastar 2.1 GB Hard Drive
Страница 2: ......
Страница 14: ...xii OEM Spec of DCAS 34330 32160...
Страница 16: ...2 OEM Spec of DCAS 34330 32160...
Страница 18: ...4 OEM Spec of DCAS 34330 32160...
Страница 19: ...Part 1 Functional Specification Copyright IBM Corp 1996 5...
Страница 20: ...6 OEM Spec of DCAS 34330 32160...
Страница 22: ...8 OEM Spec of DCAS 34330 32160...
Страница 32: ...18 OEM Spec of DCAS 34330 32160...
Страница 34: ...20 OEM Spec of DCAS 34330 32160...
Страница 56: ...6 7 1 2 68 pin Model Figure 35 Outline of 68 pin Model 42 OEM Spec of DCAS 34330 32160...
Страница 57: ...6 7 1 3 80 pin Model Figure 36 Outline of 80 pin Model Specification 43...
Страница 59: ...6 7 3 Interface Connector 6 7 3 1 50 pin Model Figure 39 Interface Connector 50 pin Model Specification 45...
Страница 60: ...6 7 3 2 68 pin Model Figure 40 Interface Connector 68 pin Model 46 OEM Spec of DCAS 34330 32160...
Страница 61: ...6 7 3 3 80 pin Model Figure 41 Interface Connector 80 pin Model Specification 47...
Страница 62: ...6 7 4 Mounting Positions and Tappings Figure 42 Mounting Positions and Tappings 48 OEM Spec of DCAS 34330 32160...
Страница 70: ...56 OEM Spec of DCAS 34330 32160...
Страница 71: ...Part 2 SCSI Interface Specification Copyright IBM Corp 1996 57...
Страница 72: ...58 OEM Spec of DCAS 34330 32160...
Страница 176: ...162 OEM Spec of DCAS 34330 32160...
Страница 178: ...164 OEM Spec of DCAS 34330 32160...
Страница 198: ...184 OEM Spec of DCAS 34330 32160...
Страница 218: ...204 OEM Spec of DCAS 34330 32160...
Страница 228: ...214 OEM Spec of DCAS 34330 32160...
Страница 232: ...IBML Part Number 73H7993 Published in Japan S73H 7993 03...