background image

Appendix A. Getting help and technical assistance

If you need help, service, or technical assistance or just want more information
about IBM products, you will find a wide variety of sources available from IBM to
assist you. Use this information to obtain additional information about IBM and IBM
products, determine what to do if you experience a problem with your IBM system
or optional device, and determine whom to call for service, if it is necessary.

Before you call

Before you call, make sure that you have taken these steps to try to solve the
problem yourself:

v

Check all cables to make sure that they are connected.

v

Check the power switches to make sure that the system and any optional
devices are turned on.

v

Check for updated firmware and operating-system device drivers for your IBM
product. The IBM Warranty terms and conditions state that you, the owner of the
IBM product, are responsible for maintaining and updating all software and
firmware for the product (unless it is covered by an additional maintenance
contract). Your IBM service technician will request that you upgrade your
software and firmware if the problem has a documented solution within a
software upgrade.

v

If you have installed new hardware or software in your environment, check
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/ to make
sure that the hardware and software is supported by your IBM product.

v

Go to http://www.ibm.com/supportportal/ to check for information to help you
solve the problem.

v

Gather the following information to provide to IBM Support. This data will help
IBM Support quickly provide a solution to your problem and ensure that you
receive the level of service for which you might have contracted. To locate the
label that contains the machine type number, the model number, and serial
number, see “Before installing the switch module” on page 6.

– Hardware and Software Maintenance agreement contract numbers, if

applicable

– Machine type number (IBM 4-digit machine identifier)

– Model number

– Serial number

– Current system UEFI and firmware levels

– Other pertinent information such as error messages and logs

v

Go to http://www.ibm.com/support/entry/portal/Open_service_request/ to submit
an Electronic Service Request. Submitting an Electronic Service Request will
start the process of determining a solution to your problem by making the
pertinent information available to IBM Support quickly and efficiently. IBM service
technicians can start working on your solution as soon as you have completed
and submitted an Electronic Service Request.

You can solve many problems without outside assistance by following the
troubleshooting procedures that IBM provides in the online help or in the
documentation that is provided with your IBM product. The documentation that
comes with IBM systems also describes the diagnostic tests that you can perform.
Most systems, operating systems, and programs come with documentation that

© Copyright IBM Corp. 2013

35

Содержание CN4093

Страница 1: ...IBM Flex System Fabric CN4093 10 Gb Converged Scalable Switch User s Guide...

Страница 2: ......

Страница 3: ...IBM Flex System Fabric CN4093 10 Gb Converged Scalable Switch User s Guide...

Страница 4: ...tion and Environmental Notices and User Guide documents on the IBM Notices for Network Devices CD and the Warranty Information document that comes with the product Second Edition August 2013 Copyright...

Страница 5: ...l console cable 15 Connecting the SFP or QSFP module cable 15 Disconnecting the SFP or QSFP module cable 15 Connecting the RJ 45 cable 15 Disconnecting the RJ 45 cable 16 Locating the information pane...

Страница 6: ...y Canada Class A emission compliance statement 43 Avis de conformit la r glementation d Industrie Canada 43 Australia and New Zealand Class A statement 43 European Union EMC Directive conformance stat...

Страница 7: ...tteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare que...

Страница 8: ...nslated versions of the caution or danger statement in the Safety Information document For example if a caution statement is labeled Statement 1 translations for that caution statement are in the Safe...

Страница 9: ...quipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instruc...

Страница 10: ...ols or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products contain an embedded Class 3A or Class 3B laser...

Страница 11: ...also usable in four 10 Gb mode to the base product v Upgrade 2 This upgrade feature adds an additional fourteen compute node ports and six uplink ports to the base product Note Upgrade 1 and Upgrade 2...

Страница 12: ...ices or data An attention notice is placed just before the instruction or situation in which damage could occur v Caution These statements indicate situations that can be potentially hazardous to you...

Страница 13: ...ch supports single compute node port capability 14 ports Dual compute node port capability 28 ports and triple compute node port capability 42 ports are available with optional licenses See Acquiring...

Страница 14: ...4 CN4093 10 Gb Converged Scalable Switch User s Guide...

Страница 15: ...h compute node with which you want to communicate To enable the switch to communicate with a compute node at least one switch must be installed in the IBM Flex System chassis For details about network...

Страница 16: ...or 10 Gbps depending on the port configuration and the transceiver module installed Before installing the switch module Locate and record information about the system interconnect module in the follow...

Страница 17: ...he IBM Flex System chassis and operating system support hot swap capability you can remove or install the component while the IBM Flex System chassis is running Orange can also indicate touch points o...

Страница 18: ...econds This drains static electricity from the package and from your body v Remove the device from its package and install it directly into the IBM Flex System chassis without setting down the device...

Страница 19: ...the switch are in the open position perpendicular to the switch 8 Slide the switch into the applicable I O bay until it stops 9 Push the release levers on the front of the switch to the closed positio...

Страница 20: ...nect any cables from the switch before you remove the switch Disconnecting these cables disrupts the network connection from the external port to any connected external devices If you plan to replace...

Страница 21: ...ocument might differ slightly from your hardware 2 While the information in this section describes the 10 Gb small form factor pluggable SFP module it also applies to the 1 Gb small form factor plugga...

Страница 22: ...e connectors for connecting to external ports To install an SFP module complete the following steps 1 Read the safety information that begins on page v and Installation guidelines on page 7 2 If you h...

Страница 23: ...from inserting the module incorrectly 3 Pull up the locking lever to lock the module into place 4 Connect the fiber optic cable To remove the QSFP module disconnect the fiber optic cable and pull dow...

Страница 24: ...er end of the cable to the console device Note You must use one of the two cables provided in the Serial Access Cable option see Cabling the switch and the SFP and QSFP modules If your attached consol...

Страница 25: ...pported To connect the SFP or QSFP module cable complete the following steps 1 Remove the protective caps from the end of the fiber optic cable Protective cap Fiber optic cable 2 Gently slide the fibe...

Страница 26: ...ion panels and LEDs on the switch and identifies the external ports on the information panels Note The illustrations in this document might differ slightly from your hardware Information panel The fro...

Страница 27: ...components v LEDs that display the following information The status of the switch Power location and fault The status of the external connections to the switch For further details about LEDs see Infor...

Страница 28: ...ssfully completed the Power LED remains on and the Error LED is off v The blue Location LED is used to identify a ScSE when prompted by the CMM Any errors that are detected during POST are written to...

Страница 29: ...ion Link LEDs Ports 1 through 22 Mgmt This green LED indicates whether the corresponding port link is up or down v When this LED is not lit it indicates that there is no signal on the corresponding po...

Страница 30: ...20 CN4093 10 Gb Converged Scalable Switch User s Guide...

Страница 31: ...ule This mode can be enabled only through the Chassis Management Module configuration interface When this mode is enabled the external SFP and QSFP ports support both management and data traffic This...

Страница 32: ...s v Unless otherwise stated references to the management module apply only to the IBM Flex System Chassis Management Module which is the only type of management module that supports the switch v Throu...

Страница 33: ...e the Web interface application see Accessing the switch through the switch browser based interface on page 25 v If your system application requires that you use the SSHv2 Telnet client software see A...

Страница 34: ...u know the IP address for the switch and you have an existing network connection you can use the SSHv2 Telnet client software from an external management station or the management module to access and...

Страница 35: ...rsal Asynchronous Receiver Transmitter UART protocol The RS 232 serial port is enabled by default Accessing the switch through the switch browser based interface Before you can access and start the br...

Страница 36: ...out configuring and managing the switch see the Command Reference for the switch Logging in to the switch The switch supports user based security that enables you to prevent unauthorized users from ac...

Страница 37: ...le CMM CLI as described in the switch s User s Guide or CLI Reference Guide for the CMM If necessary obtain the IP address of the management module from your system administrator 2 Set the environment...

Страница 38: ...rk entities TFTP SFTP server management module and switch IP addresses are on the same subnet Otherwise you must use a router and configure a gateway address on the switch Use the management module in...

Страница 39: ...l of the firmware for the switch Confirm that the firmware build number reflects the correct firmware release For example system switch 2 info Boot ROM Rel date 04 02 2013 Version 7 7 1 12 Status Acti...

Страница 40: ...history of feature activation on a selected device v Retrieve the history of feature activation on a selected authorization code v Retrieve a lost authorization code v Manage your IBM customer number...

Страница 41: ...ors noncritical and critical A noncritical error applies to one port and the switch is operational You can continue to operate the switch however you must replace it as soon as possible When critical...

Страница 42: ...ctional area Failure criticality 80 9F Internal interface failures Noncritical A0 AF External interface errors Noncritical B0 FE Reserved Noncritical FF Switch good indicator Operation 32 CN4093 10 Gb...

Страница 43: ...technicians For information about the terms of the warranty see the Warranty Information document Description CRU number Tier 1 IBM Flex System Fabric CN4093 10 Gb Converged Scalable Switch 00D5826 U...

Страница 44: ...b SFP 49Y7886 3 m 40 Gb QSFP to four 10Gb SFP 49Y7887 5 m 40 Gb QSFP to 4 x 10Gb SFP 49Y7888 10 m IBM MTP Fiber Optical 90Y3519 requires transceiver part number 49Y7884 30 m IBM MTP Fiber Optical 90Y3...

Страница 45: ...ted by your IBM product v Go to http www ibm com supportportal to check for information to help you solve the problem v Gather the following information to provide to IBM Support This data will help I...

Страница 46: ...deCenter information is http www ibm com systems bladecenter The address for IBM IntelliStation information is http www ibm com systems intellistation How to send Dynamic System Analysis data to IBM U...

Страница 47: ...tp www ibm com partnerworld and click Find Business Partners on the right side of the page For IBM support telephone numbers see http www ibm com planetwide In the U S and Canada call 1 800 IBM SERV 1...

Страница 48: ...38 CN4093 10 Gb Converged Scalable Switch User s Guide...

Страница 49: ...SS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include te...

Страница 50: ...drive capacity or communications volume MB stands for 1 000 000 bytes and GB stands for 1 000 000 000 bytes Total user accessible capacity can vary depending on operating environments Maximum internal...

Страница 51: ...evels of particulates or gases in your environment have caused damage to the switch module IBM may condition provision of repair or replacement of switch module or parts on implementation of appropria...

Страница 52: ...the monitor Federal Communications Commission FCC statement Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules Th...

Страница 53: ...ause radio interference in which case the user may be required to take adequate measures Responsible manufacturer International Business Machines Corp New Orchard Road Armonk New York 10504 914 499 19...

Страница 54: ...gt in bereinstimmung mit dem Deutschen EMVG das EG Konformit tszeichen CE zu f hren Verantwortlich f r die Einhaltung der EMV Vorschriften ist der Hersteller International Business Machines Corp New O...

Страница 55: ...unications Commission KCC statement This is electromagnetic wave compatibility equipment for business Type A Sellers and users need to pay attention to it This is for any areas other than home Russia...

Страница 56: ...46 CN4093 10 Gb Converged Scalable Switch User s Guide...

Страница 57: ...36 disconnecting RJ 45 cable 16 serial console cable 15 SFP module cable 15 documentation cable requirements 8 documentation format 42 Dynamic System Analysis 36 E electronic emission Class A notice...

Страница 58: ...ort status 19 switch status 18 switch module error 19 system status 18 LED location 16 login window Telnet interface 26 M main menu Telnet interface 26 management external ports 23 management module T...

Страница 59: ...or internal and external ports 6 parts listing 33 removing or replacing 10 resetting and restarting 29 status switch module 18 status LED 18 switch module access SSHv2 Telnet interface 24 switch modul...

Страница 60: ...50 CN4093 10 Gb Converged Scalable Switch User s Guide...

Страница 61: ......

Страница 62: ...Part Number 00AY505 Printed in USA 1P P N 00AY505...

Отзывы: