that
you
want
to
download
be
put
into
the
/etc/microcode
directory
on
the
system.
If
there
is
not
enough
space
in
the
/var
file
system
for
the
new
flash
update
image
file,
an
error
is
reported.
If
this
error
occurs,
exit
the
service
aid,
increase
the
size
of
the
/var
file
system,
and
retry
the
service
aid.
After
the
file
is
copied,
a
screen
requests
confirmation
before
continuing
with
the
flash
update.
When
you
continue
the
update
flash,
the
system
reboots
using
the
shutdown
-u
command.
The
system
does
not
return
to
the
diagnostics,
and
the
current
flash
image
is
not
saved.
After
the
reboot,
you
can
remove
the
/var/update_flash_image
file.
When
this
service
aid
is
run
from
standalone
diagnostics,
the
flash
update
image
file
is
copied
to
the
file
system
from
diskette,
optical
media,
or
from
the
NIM
server.
Using
a
diskette,
the
user
must
provide
the
image
on
backup
format
diskette
because
the
user
does
not
have
access
to
remote
file
systems
or
any
other
files
that
are
on
the
system.
If
using
the
NIM
server,
the
microcode
image
must
first
be
copied
onto
the
NIM
server
in
the
/usr/lib/microcode
directory
pointed
to
the
NIM
SPOT
(from
which
you
plan
to
have
the
NIM
client
boot
standalone
diagnostics)
prior
to
performing
the
NIM
boot
of
diagnostics.
Next,
a
NIM
check
operation
must
be
run
on
the
SPOT
containing
the
microcode
image
on
the
NIM
server.
After
performing
the
NIM
boot
of
diagnostics,
one
can
use
this
service
aid
to
update
the
microcode
from
the
NIM
server
by
choosing
the
/usr/lib/microcode
directory
when
prompted
for
the
source
of
the
microcode
that
you
want
to
update.
If
not
enough
space
is
available,
an
error
is
reported
stating
that
additional
system
memory
is
needed.
After
the
file
is
copied,
a
prompt
requests
confirmation
before
continuing
with
the
flash
update.
When
you
continue
with
the
update,
the
system
reboots
using
the
reboot
-u
command.
You
might
receive
a
″
Caution:
Some
process(es)
wouldn’t
die
″
message
during
the
reboot
process;
you
can
ignore
this
message.
The
current
flash
image
is
not
saved.
You
can
use
the
update_flash
command
in
place
of
this
service
aid.
The
command
is
located
in
the
/usr/lpp/diagnostics/bin
directory.
The
command
syntax
is
as
follows:
update_flash
[-q
|
-v]
-f
file_name
update_flash
[-q
|
-v]
-D
device_name
-f
file_name
update_flash
[-q
|
-v]
-D
update_flash
[-l]
update_flash
-c
update_flash
-r
Important:
The
update_flash
command
reboots
the
entire
system.
Do
not
use
this
command
if
more
than
one
user
is
logged
in
to
the
system.
Flag
descriptions
are
as
follows:
Flag
Description
-D
Specifies
that
the
flash
update
image
file
is
on
diskette.
The
device_name
variable
specifies
the
device.
The
default
device_name
is
/dev/fd0.
-f
Flash
update
image
file
source.
The
file_name
variable
specifies
the
fully
qualified
path
of
the
flash
update
image
file.
-l
Lists
the
files
on
a
diskette,
from
which
the
user
can
choose
a
flash
update
image
file.
-q
Forces
the
update_flash
command
to
update
the
flash
EPROM
and
reboot
the
system
without
asking
for
confirmation.
-v
Validates
the
flash
update
image.
No
update
will
occur.
66
BladeCenter
JS20
Type
8842:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Содержание BladeCenter JS20
Страница 1: ...BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 6: ...iv BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 22: ...12 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 30: ...20 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 68: ...58 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 183: ...Appendix B Safety information 173...
Страница 184: ...174 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 185: ...Appendix B Safety information 175...
Страница 186: ...176 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 187: ...Appendix B Safety information 177...
Страница 188: ...178 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 189: ...Appendix B Safety information 179...
Страница 190: ...180 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 200: ...190 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 201: ...Appendix B Safety information 191...
Страница 202: ...192 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 203: ...Appendix B Safety information 193...
Страница 212: ...202 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 217: ......
Страница 218: ...Part Number 90P3485 Printed in USA 1P P N 90P3485...