2.
BladeCenter
JS20
models
that
are
designed
for
the
NEBS
environment
contain
a
power-management
capability
that
provides
the
maximum
possible
operating
time
for
your
system.
Power
management
is
invoked
only
when
the
blade
server
is
installed
in
a
BladeCenter
T
unit
and
only
under
the
short
term
extended
thermal
conditions
that
are
described
in
the
preceding
table
as
"short
term"
in
the
high
end
of
the
NEBS
extended
temperature
range,
40°
to
55°C
(104°
to
131°F).
Instead
of
shutting
down
or
failing
in
short
term
extended
thermal
conditions,
the
JS20
blade
server
automatically
reduces
the
frequency
of
the
processor
to
maintain
acceptable
thermal
levels.
The
processor
frequency
automatically
returns
to
normal
as
thermal
conditions
improve.
The
BladeCenter
management
module
is
notified
when
power
management
starts
and
again
when
it
stops.
The
following
entries
are
made
in
the
event
log:
v
Frequency
throttling
process
is
now
active.
(This
message
indicates
that
power
reduction
is
in
effect.)
v
Frequency
throttling
process
is
now
idling.
(This
message
indicates
that
power
reduction
was
previously
invoked
but
is
no
longer
in
effect.)
Do
not
restart
the
blade
server
when
power
reduction
is
in
effect.
3.
Some
applications
are
sensitive
to
processor
frequency
changes.
Check
with
your
application
vendors
to
determine
if
there
are
any
possible
impacts
to
your
applications
from
the
effects
of
the
JS20
blade
server
power-management
capability
in
the
short
term
extended
thermal
conditions
of
the
NEBS
environment.
8
BladeCenter
JS20
Type
8842:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Содержание BladeCenter JS20
Страница 1: ...BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 6: ...iv BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 22: ...12 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 30: ...20 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 68: ...58 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 183: ...Appendix B Safety information 173...
Страница 184: ...174 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 185: ...Appendix B Safety information 175...
Страница 186: ...176 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 187: ...Appendix B Safety information 177...
Страница 188: ...178 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 189: ...Appendix B Safety information 179...
Страница 190: ...180 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 200: ...190 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 201: ...Appendix B Safety information 191...
Страница 202: ...192 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 203: ...Appendix B Safety information 193...
Страница 212: ...202 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 217: ......