Table 5. Service Processor Error Codes. (continued)
Error Code Description
Action/
Possible Failing FRU
406C 0EB6 Attention line 5 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
406C 0EB7 Attention line 6 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
406C 0EB8 Attention line 7 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
406C 0EB9 Attention line 8 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
406C 0EBA Attention line 9 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
406C 0EBB Attention line 10 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
406C 0EBC Attention line 11 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
406C 0EBF
Description:
Memory error
Action:
1. Reboot the system in slow mode to the SMS menus. See “Performing Slow Boot” on page 209.
2. Examine the service processor error log.
v
If a CEC subsystem error (a 4xxx yyyy error) occurred during the slow boot that calls out the
memory, processors, L3 cache modules or the primary I/O book, replace the part indicated
by the location code.
v
If a CEC subsystem error (a 4xxx yyyy error) did not occur during the slow boot, look for a
4xxx yyyy error immediately preceding the 406C 0EBF error. Replace the part indicated by
the location code associated with that error.
406C 0EE1 Service processor firmware: invalid MRU to FRU
mapping
1. Check for system firmware updates.
2. Call service support.
406C 0EE2 Service processor firmware fault
1. Check for system firmware updates.
2. Call service support.
406C 0EE5 Firmware error, no callout available
1. Check for system firmware updates.
2. Call service support.
406D 0001 Scan interface basic assurance tests detected a
CEC backplane fault
CEC backplane
Location: U0.1-P1
406D 0002 CEC backplane fault
1. Check JTAG cable connections
2. CEC backplane
Location: U0.1-P1
406D 0003 Scan interface basic assurance tests detected
processor fault
1. Check JTAG cable connections.
2. Processor card
Location: U0.1-P1-C1
406D 0004 Processor fault
1. Check JTAG cable connections.
2. Processor card
Location: U0.1-P1-C2
406D 000E Processor capacity card
Operator Panel
Location: U0.1-L1
294
Eserver
pSeries 630 Model 6C4 and Model 6E4 Service Guide
Содержание @Server pSeries 630 6E4
Страница 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver ...
Страница 2: ......
Страница 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver ...
Страница 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 535: ...Chapter 10 Parts Information This chapter contains parts information for the pSeries 630 Model 6C4 and Model 6E4 515 ...
Страница 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 541: ...Chapter 10 Parts Information 521 ...
Страница 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 649: ......
Страница 650: ... Printed in U S A May 2003 SA38 0604 03 ...