![IBM @Server pSeries 630 6E4 Скачать руководство пользователя страница 254](http://html.mh-extra.com/html/ibm/atserver-pseries-630-6e4/atserver-pseries-630-6e4_service-manual_608170254.webp)
Table 4. Firmware Error Codes. (continued)
Error Code Description
Action/
Possible Failing FRU
20EE 0020 The environment variable
″
boot-device
″
exceeds the allowed character limit.
If this error occurs during the installation of AIX
via a
″
NIM push
″
, the set_bootlist attribute may
not have been set correctly on the NIM master.
For more information, see the
AIX Installation
Guide and Reference
, order number
SC23-4389.
If this error occurs at any other time:
1. Check for platform firmware updates. Apply
if available.
2. Call service support.
20EE 0021 The environment variable
″
boot-device
″
contained more than five entries.
If this error occurs during the installation of AIX
via a
″
NIM push
″
, the set_bootlist attribute may
not have been set correctly on the NIM master.
For more information, see the
AIX Installation
Guide and Reference
, order number
SC23-4389.
If this error occurs at any other time:
1. Check for platform firmware updates. Apply
if available.
2. Call service support.
20EE 0022 The environment variable
″
boot-device
″
contained an entry that exceeded 255
characters in length.
If this error occurs during the installation of AIX
via a
″
NIM push
″
, the set_bootlist attribute may
not have been set correctly on the NIM master.
For more information, see the
AIX Installation
Guide and Reference
, order number
SC23-4389.
If this error occurs at any other time:
1. Check for platform firmware updates. Apply
if available.
2. Call service support.
20EE 0100 Fcode resident on an I/O adapter is not
supported on this system
Informational message. The adapter’s Fcode
driver is not supported on this system.
Additional information may be available from
service support.
This error code only affects boot-time operation,
not the adapter’s functionality under the
operating system.
20FC 0020 Failed to retrieve power, packaging, and/or
cooling VPD via SPCN for the corresponding
subsystem.
Service processor mailbox failed to get VPD.
1. Check the RIO cabling.
2. Check for system firmware updates.
3. Replace the RIO riser card (location:
U0.
dd
-P1.1) in the I/O subsystem that the
RIO cable in step 1 is attached to.
4. Replace the I/O backplane that the RIO
cable in step 1 is attached to.
5. Replace the CEC backplane, U0.1-P1.
234
Eserver
pSeries 630 Model 6C4 and Model 6E4 Service Guide
Содержание @Server pSeries 630 6E4
Страница 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver ...
Страница 2: ......
Страница 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver ...
Страница 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 535: ...Chapter 10 Parts Information This chapter contains parts information for the pSeries 630 Model 6C4 and Model 6E4 515 ...
Страница 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 541: ...Chapter 10 Parts Information 521 ...
Страница 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 649: ......