Table 4. Firmware Error Codes. (continued)
Error Code Description
Action/
Possible Failing FRU
21F2 0001 SCSI read/write optical - test unit ready failed -
hardware error
Before replacing any system components, refer
to the notes in error code 21A0 0001.
1. Replace the SCSI device.
2. Replace the SCSI cable.
3. Replace the SCSI controller.
21F2 0002 SCSI read/write optical - test unit ready failed -
sense data available
Before replacing any system components, refer
to the notes in error code 21A0 0001.
1. Replace the media.
2. Replace the SCSI device.
21F2 0003 SCSI read/write optical - send diagnostic failed-
sense data available
Before replacing any system components, refer
to the notes in error code 21A0 0001.
Replace the SCSI device.
21F2 0004 SCSI read/write optical - send diagnostic failed-
DevOfl cmd
Before replacing any system components, refer
to the notes in error code 21A0 0001.
Replace the SCSI device.
2200 0001 PCI Ethernet BNC/RJ-45 or PCI Ethernet
AUI/RJ-45 adapter
internal wrap test failure
Replace the adapter.
See “Checkpoint and Error Code Index” on
page 213 for location code information related
to this error. Also see “Replacing the Network
Adapter” on page 211.
2200 1001 10/100 Mbps Ethernet PCI Adapter
internal wrap test failure
Replace the adapter.
See “Checkpoint and Error Code Index” on
page 213 for location code information related
to this error. Also see “Replacing the Network
Adapter” on page 211.
2200 1002 10/100 Mbps Ethernet PCI adapter failure
Replace the adapter.
See “Checkpoint and Error Code Index” on
page 213 for location code information related
to this error. Also see “Replacing the Network
Adapter” on page 211.
2201 0001 PCI Auto LANstreamer token ring adapter failed
to complete hardware initialization.
Replace the adapter.
See “Checkpoint and Error Code Index” on
page 213 for location code information related
to this error. Also see “Replacing the Network
Adapter” on page 211.
2201 1001 PCI token ring adapter failed to complete
hardware initialization.
Replace the adapter.
See “Checkpoint and Error Code Index” on
page 213 for location code information related
to this error. Also see “Replacing the Network
Adapter” on page 211.
25A0 0001 Cache L2 controller failure
1. Replace the processor card.
Location: U0.1-P1-C1
2. Replace the CEC backplane assembly.
Location: U0.1-P1.
25A1 0001 Cache L2 SRAM failure
1. Replace the processor card.
Location: U0.1-P1-C1
240
Eserver
pSeries 630 Model 6C4 and Model 6E4 Service Guide
Содержание @Server pSeries 630 6E4
Страница 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver ...
Страница 2: ......
Страница 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver ...
Страница 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 535: ...Chapter 10 Parts Information This chapter contains parts information for the pSeries 630 Model 6C4 and Model 6E4 515 ...
Страница 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 541: ...Chapter 10 Parts Information 521 ...
Страница 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Страница 649: ......
Страница 650: ... Printed in U S A May 2003 SA38 0604 03 ...