136
IBM Certification Study Guide AIX HACMP
• Generate the switch error in the error log which is being monitored by
HACMP Error Notification (for configuration see 2.6.2.1, “Single
Point-of-Failure Hardware Component Recovery” on page 46), or, if the
network_down event has been customized, bring down css0 (
ifconfig
css0 down
) or fence out NodeF from the Control Workstation (
Efence NodeF
).
• If the first failure simulation method is used, the switch failure will be
detected in the error log (
errpt -a | more
) on NodeF and cause a node
failover to NodeT. The other two methods will cause HACMP to detect a
network_down event, with the same result. (Note that if there is another
node in the cluster with a lower alphanumeric node name than NodeT,
then that node will become Eprimary. HACMP does not take care of the
Eprimary if a new SP-Switch is used).
• Verify that failover has occurred (
netstat -i
and
ping
for networks,
lsvg -o
and
vi
of a test file for volume groups,
ps -U <appuid>
for application
processes, and
Eprimary
for Eprimary).
• Start HACMP on NodeF (
smit clstart
). NodeT will release NodeF's
cascading Resource Groups and NodeF will take them back over, but
NodeT (or a lower alphanumeric node) will remain Eprimary.
• Verify that re-integration has occurred (
netstat -i
and
ping
for networks,
lsvg -o
and
vi
of a test file for volume groups,
ps -U <appuid
> for
application processes, and
Eprimary
for Eprimary).
6.2.1.4 Failure of a 7133 Adapter
Perform the following steps in the event of a 7133 Adapter failure:
• Check, by way of the verification commands, that all the Nodes in the
cluster are up and running.
• Optional: Prune the error log on NodeF (
errclear 0
).
• Monitor cluster logfiles on NodeT if HACMP has been customized to
monitor 7133 disk failures.
• Pull all the cable from the SSA adapter.
• The failure of the 7133 adapter should be detected in the error log (
errpt
-a | more
) on NodeF or should be noted in the appropriate diagnostics
tool, and the logical volume copies on the disks in drawer 1 will be marked
stale (
lsvg -l NodeFvg
).
• Verify that all sharedvg file systems and paging spaces are accessible (
df
-k
and
lsps -a
).
• Re-attach the cables.
Содержание AIX HACMP
Страница 2: ......
Страница 10: ...viii IBM Certification Study Guide AIX HACMP...
Страница 12: ...x IBM Certification Study Guide AIX HACMP...
Страница 14: ...xii IBM Certification Study Guide AIX HACMP...
Страница 18: ...xvi IBM Certification Study Guide AIX HACMP...
Страница 24: ...6 IBM Certification Study Guide AIX HACMP...
Страница 110: ...92 IBM Certification Study Guide AIX HACMP...
Страница 133: ...HACMP Installation and Cluster Definition 115...
Страница 134: ...116 IBM Certification Study Guide AIX HACMP...
Страница 160: ...142 IBM Certification Study Guide AIX HACMP...
Страница 200: ...182 IBM Certification Study Guide AIX HACMP...
Страница 216: ...198 IBM Certification Study Guide AIX HACMP...
Страница 222: ...204 IBM Certification Study Guide AIX HACMP...
Страница 226: ...208 IBM Certification Study Guide AIX HACMP...
Страница 232: ...214 IBM Certification Study Guide AIX HACMP...
Страница 240: ...Printed in the U S A SG24 5131 00 IBM Certification Study Guide AIX HACMP SG24 5131 00...