Industrial-grade, long-range wireless Ethernet systems

AW58EMVAP 

AW584EMVSU 

Wireless Forecourt Access Point and 

Wireless Wireless In-Dispenser Unit 

with Network Switch

Содержание AW584EMVSU

Страница 1: ...USER S MANUAL Industrial grade long range wireless Ethernet systems AW58EMVAP AW584EMVSU Wireless Forecourt Access Point and Wireless Wireless In Dispenser Unit with Network Switch ...

Страница 2: ...ically lock restrict access to or tag the circuit breakers you turn off when servicing the dispenser Be sure to trip close the emergency valve s under the dispenser BEFORE beginning maintenance Make sure that you know how to turn OFF power to the dispenser and submersible pumps in an emergency Have all leaks or defects repaired immediately HOW TO CONTACT AVALAN WIRELESS Problems with the installat...

Страница 3: ...CKING AND INSPECTION 5 RETURNING DAMAGED COMPONENTS 6 SAFETY INFORMATION 7 INSTALLATION LOCATION 8 CONFORMITY AND STANDARDS 9 REQUIRED TOOLS 9 REQUIRED PARTS 9 INSTALLATION OVERVIEW 10 INSTALLATION PROCEDURE 11 Shutdown the Site 11 AW584EMVSU Installation 11 Wall Mounting 11 Connecting to the Ethernet Ports 11 Site Startup 11 Table of Contents ...

Страница 4: ...nstallation of several wiring and hardware assemblies Any installation or modification must comply with the requirements of the National Electrical Code NFPA 70 the Automotive and Marine Service Station Code NFPA 30A and any other applicable codes NOTE You must wear a static wrist strap securely attached to an earth ground when handling any circuit board electronic component or assembly or when re...

Страница 5: ...l it is certain that return shipments are not required Returning Damaged Components Parts or components returned to the factory under warranty or for repair are subject to damage if not packaged properly Complete the following steps to return parts or components to the production facility 1 Place electronic components in an anti static bag and in the original shipping cartons for return shipment t...

Страница 6: ...nual CSA C22 1 Canadian Electrical Code and applicable federal provincial and local codes and regulations Emergency Power Cutoff NFPA30A requires that an emergency power cutoff be installed An emergency power cutoff is a single control that removes AC power from all site fueling equipment and submersible pumps Make sure the control is accessible labeled clearly and installed away from dispensers M...

Страница 7: ...ooling 3 away from other equipment Environmental Requirements Care should be taken to ensure that the temperature of the cabinets does not exceed the operational ranges of 40 C to 70 C 40 F to 158 F Power Requirements The DC power source to the AW584EMVSU device must have an input voltage of 24VDC Installation Location for Access Point XXXXX Environmental Requirements Care should be taken to ensur...

Страница 8: ... the Emergency Stop button is pressed The Emergency Stop Circuit wiring should be configured according to local electrical regulations Codes Confirm that all equipment is installed in accordance with the US National Electrical Code NFPA 70 the automotive and Marine Service Station Code NFPA 30A and any other applicable state and local codes For installations outside the US follow all applicable lo...

Страница 9: ...onnect to the Wayne Fuel Dispenser s 24VDC power panel 3 The cables provided with the product shall be reliably routed separate 50mm from other wiring cabling within the dispenser unless all wiring insulation is rated for the highest circuit voltage 4 The Earthing conductor shall be minimum 18AWG and copper only 5 Only use the supplied cable to power device 6 The power supply should be Class 2 or ...

Страница 10: ...w avalan com Mounting Kit Plate Quick Disconnect Bracket AW584EMVSU Radio USB Key Power Cable Mounting Adhesive Screws What s in the Box AW584EMVSU AW58EMVAP Quick Disconnect Bracket Mounting Adhesive Screws Power Supply POE Injector Mounting Kit Plate AW58EMVAP Radio Antennas ...

Страница 11: ...clean the prospective mounting surface removing any oils dirt or residue ___ 5 After selecting a mounting location attach the AW58EMVMK metal mounting bracket to the wall by removing the backing from the adhesive and placing it with the tab oriented upwards ___ 6 Hook the opening on the plastic mounting plate over the tab of the metal mounting bracket ___ 7 Remove the USB key off the Subscriber Un...

Страница 12: ...ds to confirm proper adhesion ___ 6 Connect networking cable from the port in the AP to the female connector on the POE Injector Note CAT 6 recommended and up to 100 meters supported ___ 7 Insert the lip from the Quick Disconnect Bracket into the horiztonal opening at the top of AP ___ 8 Connect the male connector on the POE Injector to your existing switch ___ 9 Connect 24 VDC power supply at 120...

Страница 13: ...ble with internet access To register the Access Point use the serial number shown on the front of the enclosure A minute after registering the Access Point the status of the site will be automatically updated The dispensers that are wirelessly connected to the access point will display their USB Key ID and signal strength The USB Key ID is printed on the USB Stick that came with each radio Users s...