Figure 20. Installing a DOM
3. Prepare the system for operation. For instructions, see “Preparing the 5104-22C, 9006-22C, or
9006-22P system for operation after you remove and replace internal parts” on page 107.
4. For a non-RAID drive, configure the installed drive for your environment. If the drive is part of a RAID
configuration, skip this step, the drive is detected and configured when inserted.
After you insert the new drive, you need to rescan for the device.
Ubuntu Linux operating system
To run the
rescan-scsi-bus
command in the Ubuntu Linux operating system, log in to the
system as the root user, and run the following command:
rescan-scsi-bus
The
rescan-scsi-bus
tool is available in the
scsitools
package; install the package by using
the following command:
sudo apt-get install scsitools
Red Hat Enterprise Linux (RHEL) version 7.2
To run the rescan command in the REHL version 7.2 operating system, log in to the system as the
root user, and run the following command:
rescan-scsi-bus.sh -a
Installing and configuring your system and system features 25
Содержание 9006-22C
Страница 1: ...Power Systems Installing and configuring the IBM Power System LC922 9006 22P IBM...
Страница 14: ...xiv Power Systems Installing and configuring the IBM Power System LC922 9006 22P...
Страница 112: ...98 Power Systems Installing and configuring the IBM Power System LC922 9006 22P...
Страница 120: ...or or or 106 Power Systems Installing and configuring the IBM Power System LC922 9006 22P...
Страница 136: ...122 Power Systems Installing and configuring the IBM Power System LC922 9006 22P...
Страница 147: ......
Страница 148: ...IBM...