Chapter 1. Technical overview
45
On the back of the server, the top port is Ethernet 1 and the bottom is Ethernet 2.
The LEDs for these ports are shown in Figure 1-19.
Figure 1-19 Onboard dual-port Gigabit Ethernet controller
The LEDs indicate status as follows:
LED Blink = port has activity
LED On = port is linked
LED Off = port is not linked
1.11.2 Redundancy features
The x3850 M2 and x3950 M2 have the following redundancy features to maintain
high availability:
Six hot-swap, multispeed fans provide cooling redundancy and enable
individual fan replacement without powering down the server. Each of the
three groups of two fans is redundant. In the event of a fan failure, the other
fans speed up to continue to provide adequate cooling until the fan can be
hot-swapped by the IT administrator. In general, failed fans should be
replaced within 48 hours following failure.
The two Gigabit Ethernet ports can be configured as a team to form a
redundant pair.
The memory subsystem has a number of redundancy features, including
memory mirroring and Memory ProteXion, as described in 1.8, “Memory
subsystem” on page 39.
RAID disk arrays are supported for both servers, each with the onboard LSI
1078 for RAID-0 and RAID-1. The optional ServeRAID MR10k provides
additional RAID features and a 256 MB battery-backed cache. The x3850 M2
and x3950 M2 has four internal, hot-swap disk drive bays.
The two, standard 1440 W hot-swap power supplies are redundant in all
configurations at 220 V. At 110 V, each power supply draws approximately
720 W and the second power supply is not redundant.
LED for port 1
(triangle pointing up)
Ethernet 2
Ethernet 1
LED for port 2
(triangle pointing
down)
Содержание 88743BU - System x3950 E
Страница 2: ......
Страница 10: ...viii Planning Installing and Managing the IBM System x3950 M2 ...
Страница 14: ...xii Planning Installing and Managing the IBM System x3950 M2 ...
Страница 106: ...88 Planning Installing and Managing the IBM System x3950 M2 ...
Страница 262: ...244 Planning Installing and Managing the IBM System x3950 M2 Figure 4 36 IBM System x technical support on the Web ...
Страница 309: ...Chapter 5 Installation 291 Figure 5 36 Select type of installation Upgrade or Custom clean installation ...
Страница 316: ...298 Planning Installing and Managing the IBM System x3950 M2 ...
Страница 398: ...380 Planning Installing and Managing the IBM System x3950 M2 ...
Страница 423: ... 0 5 spine 0 475 0 875 250 459 pages Planning Installing and Managing the IBM System x3950 M2 ...
Страница 424: ......
Страница 425: ......