![IBM 88743BU - System x3950 E Скачать руководство пользователя страница 183](http://html1.mh-extra.com/html/ibm/88743bu-system-x3950-e/88743bu-system-x3950-e_user-manual_3861387183.webp)
Chapter 3. Hardware configuration
165
CC Rate:
48
is the default
This indicates the amount of system resources dedicated to consistency
checking (CC) of virtual disks connected to the selected adapter. The value
can be 1-100%.
Reconstruction Rate:
48
is the default
This is where you define the reconstruction rate of physical drives to the
selected adapter dedicated to the amount of system resources. The value can
be 1-100%.
Adapter BIOS:
Enabled
is the default
This enables or disables the Adapter BIOS. If the selected controller is
connected to the boot drive, then Adapter BIOS must be enabled on that
controller.
Coercion Mode:
1GB-way
is the default
This forces physical disks of varying capacities to the same size so that they
can be used in the same array.
The Coercion Mode can be set to None, 128 MB-way, and 1 GB-way. This
number depends on how much the drives from various vendors vary in their
actual size.
PDF Interval:
300
(seconds) is the default (this equals 5 minutes)
This specifies how frequently the controller polls for physical drives report a
Predictive Drive Failure (PDF) Self-Monitoring, Analysis and Reporting
Technology (S.M.A.R.T.) error.
Alarm Control: Disabled is the default
This enables, disables, or silences the onboard alarm tone generator on the
controller.
Patrol Read Rate:
48
is the default
Tip:
If more than one controller is installed (for example, in a x3950 M2
complex), one of them typically owns the bootable device.
We recommend that you enable Adapter BIOS only on the controller that
contains the boot device, and disable it on all others. This maximizes the
available PCI ROM space and reduces the chance of getting PCI ROM
Allocation errors.
Note:
LSI recommends that you use the 1 GB-way setting.
Содержание 88743BU - System x3950 E
Страница 2: ......
Страница 10: ...viii Planning Installing and Managing the IBM System x3950 M2 ...
Страница 14: ...xii Planning Installing and Managing the IBM System x3950 M2 ...
Страница 106: ...88 Planning Installing and Managing the IBM System x3950 M2 ...
Страница 262: ...244 Planning Installing and Managing the IBM System x3950 M2 Figure 4 36 IBM System x technical support on the Web ...
Страница 309: ...Chapter 5 Installation 291 Figure 5 36 Select type of installation Upgrade or Custom clean installation ...
Страница 316: ...298 Planning Installing and Managing the IBM System x3950 M2 ...
Страница 398: ...380 Planning Installing and Managing the IBM System x3950 M2 ...
Страница 423: ... 0 5 spine 0 475 0 875 250 459 pages Planning Installing and Managing the IBM System x3950 M2 ...
Страница 424: ......
Страница 425: ......