v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Lit
light
path
diagnostics
LED
with
the
system-error
LED
also
lit
Description
Action
MEM
Memory
failure.
Note:
The
error
LED
on
the
memory
card
is
also
lit.
1.
Remove
the
memory
card
with
the
lit
error
LED
on
the
top
of
the
card;
then,
press
the
light
path
button
on
the
memory
card
to
identify
the
failed
card
or
DIMM.
2.
Reseat
the
DIMM.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Memory
board
b.
DIMM
c.
(Trained
service
technician
only)
Microprocessor
tray
NMI
A
hardware
error
has
been
reported
to
the
operating
system.
Note:
The
PCI
or
MEM
LED
might
also
be
lit.
1.
See
the
BMC
log
and
the
system-error
log.
2.
If
the
PCI
LED
is
lit,
follow
the
instructions
for
that
LED.
3.
If
the
MEM
LED
is
lit,
follow
the
instructions
for
that
LED.
4.
Restart
the
server.
PCI
A
PCI
adapter
has
failed.
Note:
The
error
LED
next
to
the
failing
adapter
on
the
PCI-X
board
is
also
lit.
1.
See
the
BMC
log
or
the
system-error
log.
2.
Reseat
the
following
components:
a.
Failing
adapter
b.
I/O
board
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
SP
There
is
a
fault
in
the
Remote
Supervisor
Adapter
II
SlimLine.
1.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine.
2.
Update
the
firmware
for
the
Remote
Supervisor
Adapter
II
SlimLine.
3.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
DASD
A
hard
disk
drive
has
failed
or
has
been
removed.
Note:
The
error
LED
on
the
failing
hard
disk
drive
is
also
lit.
1.
Reinstall
the
removed
drive.
2.
Reseat
the
following
components:
a.
Failing
hard
disk
drive
b.
SAS
hard
disk
drive
backplane
c.
SAS
6x
cable
d.
I/O
board
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
64
IBM
xSeries
366
Type
8863:
Installation
Guide
Содержание 8863 - eServer xSeries 366
Страница 3: ...IBM xSeries 366 Type 8863 Installation Guide...
Страница 18: ...6 IBM xSeries 366 Type 8863 Installation Guide...
Страница 58: ...46 IBM xSeries 366 Type 8863 Installation Guide...
Страница 60: ...48 IBM xSeries 366 Type 8863 Installation Guide...
Страница 78: ...66 IBM xSeries 366 Type 8863 Installation Guide...
Страница 88: ...76 IBM xSeries 366 Type 8863 Installation Guide...
Страница 92: ...80 IBM xSeries 366 Type 8863 Installation Guide...
Страница 93: ......
Страница 94: ...Part Number 31R1515 Printed in USA 1P P N 31R1515...