IBM® Netfinity® 5100 User’s Reference
POST
289
An error occurred during POST memory tests and a failing DIMM was disabled.
Note:
You can use the server with decreased memory.
Action:
1. If you just installed memory, verify that the new memory is correct for
your server. Also verify that the memory is installed and seated
correctly. Start the Configuration/Setup Utility program and select
Memory Settings
from the Advanced Setup menu to enable the
DIMM.
2. If the problem remains, replace the failing DIMM.
If the problem persists, call for service.
301
303
An error occurred during the keyboard and keyboard controller test. These error
messages also might be accompanied by continuous beeping.
Action:
Ensure that:
1. Nothing is resting on the keyboard and pressing a key.
2. No key is stuck.
3. The keyboard cable is connected correctly to the keyboard and to the
correct connector on the server.
Running the diagnostic tests can isolate the server component that failed, but you must
have your system serviced. If the error message remains, call for service.
Note:
If you just connected a new mouse or other pointing device, turn off the server
and disconnect that device. Wait at least 5 seconds; then, turn on the server. If
the error message goes away, replace the device.
602
Invalid diskette boot record
Action:
1. Replace the diskette.
2. If the problem persists, make sure that the diskette drive cables are
correctly and securely connected.
3. If the problem remains, replace the diskette drive.
If the problem persists, call for service.
604
An error occurred during a diskette drive test.
Action:
1. Verify that the Configuration/Setup Utility program correctly reflects
the type of diskette drive that you have installed.
2. Run the diagnostic tests. If the diagnostic tests fail, call for service.
662
A diskette drive configuration error occurred.
Action:
If you removed a diskette drive, make sure that the diskette drive setting is
correct in the Configuration/Setup Utility program. If the setting is not
correct, change it.
If the problem persists, call for service.
962
A parallel port configuration error occurred.
Action:
If you changed a hardware option, make sure that the parallel port setting
is correct in the Configuration/Setup Utility program. If the setting is not
correct, change it.
If the problem persists, call for service.
POST message
Description
Table 14. POST error messages
Содержание 5100
Страница 1: ...IBM IBM Netfinity 5100 User s Reference SC19 K080 70...
Страница 2: ......
Страница 3: ...IBM IBM Netfinity 5100 User s Reference SC19 K080 70...
Страница 8: ...IBM Netfinity 5100 User s Reference...
Страница 14: ...xii IBM Netfinity 5100 User s Reference...
Страница 24: ...10 IBM Netfinity 5100 User s Reference Operator information panel...
Страница 36: ...22 IBM Netfinity 5100 User s Reference Using the SCSISelect utility program...
Страница 74: ...60 IBM Netfinity 5100 User s Reference Netfinity Manager...
Страница 190: ...176 IBM Netfinity 5100 User s Reference Getting help service and information...
Страница 210: ...196 IBM Netfinity 5100 User s Reference Product warranties and notices...
Страница 213: ......